Safety evaluation of femtosecond lentotomy on the porcine lens by optical measurement with 50-femtosecond laser pulses.

نویسندگان

  • Jiaying Zhang
  • Rui Wang
  • Bing Chen
  • Peng Ye
  • Wei Zhang
  • Hongyou Zhao
  • Jie Zhen
  • Yifei Huang
  • Zhiyi Wei
  • Ying Gu
چکیده

BACKGROUND AND OBJECTIVE The optimized parameters of femtosecond (fs) lentotomy, an innovative strategy for presbyopia, have been further discussed regarding the safety of the procedure for eyeballs. This article's aim was to prove the safety and feasibility of the fs lentotomy procedure with 50-fs laser pulses. STUDY DESIGN/MATERIALS AND METHODS This was an experimental study in which the safety of fs lentotomy by optical measurement was tested. The experiment was performed on 49 porcine crystalline lenses by 50-fs laser pulses at a central wavelength of 800 nm and scanning focusing optics with a numerical aperture (NA) of 0.125. The input pulse energy was in the range of 0.35 μJ to 0.65 μJ. The transmitted energy throughout the eyeball was measured through a hole in the back wall of the eyeball by a power meter. The transmittance and peak power density (PPD) on the cornea, lens, and retina were illustrated. The laser cutting quality of 50-fs laser pulses on the crystalline lens were assessed, and the theoretical safety of such a procedure for the cornea, lens, and retina was evaluated. RESULTS A sharp cut without noticeable large bubbles was obtained with 0.35 μJ pulse energy under the optical system for which the NA was 0.125. The transmittance of the whole eyeball was measured to be 69% to 75% under 0.35 μJ to 0.65 μJ incident laser energy. The threshold of PPD for photodisruption on the crystalline lens, retina, and cornea was measured to be in the magnitude of 10(13)  W/cm(2) , 10(8)  W/cm(2) , and 10(9)  W/cm(2) , respectively. CONCLUSIONS The cutting quality in this experiment implied the feasibility of the 50-fs laser in fs lentotomy; the pulse energy for fs lentotomy descended from microjoules to hundreds of nanojoules, and the PPD on the cornea and retina during the procedure decreased further, both of which illustrated the safety of such an optical design and the parameters during fs lentotomy for the eyeball.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Ex Vivo Porcine Lens Shape During Simulated Accommodation, Before and After fs-Laser Treatment.

PURPOSE According to Helmholtz, accommodation is based on the flexibility of the crystalline lens, which decreases with age, causing presbyopia. With femtosecond (fs)-lentotomy treatment, it is possible to restore the flexibility of presbyopic lenses. The efficiency of the treatment can be systematically evaluated using the finite element method based on experimental data. The purpose of this s...

متن کامل

The study of propagation of a femtosecond laser pulse in the breast tissue

In this paper, the evaluation of time profile of a femtosecond pulse laser propagated through biological tissues is studied. The majority of the biological tissues with a high scattering anisotropy must be considered as turbid media, that their optical responses are complicated. To study the propagation of ultra-short pulse in turbid media, the diffuse equation is used. In this study, the analy...

متن کامل

Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery.

PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...

متن کامل

Femtosecond Kerr-lens autocorrelation.

An autocorrelation measurement of femtosecond laser pulse duration using the Kerr-lens mechanism is demonstrated. This technique can also be used as a sensitive and absolutely calibratable method for measuring ultrafast optical nonlinearities. A method that uses an electronic spectral-filtering scheme is proposed for determining the frequency chirp of pulses by interferometric autocorrelation.

متن کامل

Square Lattice Elliptical- Core Photonic Crystal Fiber Soliton-Effect Compressor at 1550nm

 In this paper, we investigate the evolution of supercontinuum and femtosecond optical pulses generation through square lattice elliptical-core photonic crystal fiber (PCF) at 1550 nm by using both full-vector multipole method (M.P.M) and novel concrete algorithms: symmetric  split-step Fourier (SSF) and  fourth order Runge Kutta (RK4) which is an accurate method to solve the general  nonlinear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 45 7  شماره 

صفحات  -

تاریخ انتشار 2013