Observational study of patient and surgeon preoperative preparation in ten companion animal clinics in Ontario, Canada

نویسندگان

  • Maureen E C Anderson
  • Brittany A Foster
  • J Scott Weese
چکیده

BACKGROUND Surgical site infections (SSIs) are a recognized risk of any surgical procedure in veterinary medicine. One of the keys to prevention of SSIs is reducing exposure of the surgical site to endogenous and exogenous microbes, beginning in the preoperative period. While guidelines are available for preoperative preparation procedures, there has been no objective investigation of compliance with these recommendations in veterinary practices. The objectives of this pilot study were to describe preoperative patient and surgeon preparation practices in a sample of non-equine companion animal veterinary clinics, and to determine if there were any areas that consistently did not meet current guidelines. RESULTS Observation of preparation practices was performed in 10 clinics over 9-14 days each using up to 3 small wireless surveillance cameras. Data were coded for 148 surgical patients, and 31 surgeons performing 190 preoperative preparations. When patient hair removal was observed, it was most commonly done using clippers (117/133, 88%), and in only one case was it performed prior to anesthetic induction. Patient contact time with soap ranged from 10-462 s (average of clinic means 75 s, average of clinic medians 67 s), and with alcohol from 3-220 s (average of clinic means 44 s, average of clinic medians 37 s). Alcohol-based hand rub (AHR) was used preoperatively in 2/10 facilities, but soap-and-water hand scrub was most commonly used at all clinics. Proximal-to-distal scrubbing was noted in 95/142 (67%) of soap-and-water scrubs. Contact time during surgeon hand preparation ranged from 7-529 s (average mean 121 s, average median 122 s) for soap-and-water and from 4-123 s (average mean 25 s, average median 19 s) for AHR. No significant changes in practices were identified over time during the observation period. Practices that did not conform to guidelines available in major companion animal surgical textbooks were commonly observed. CONCLUSIONS Some preoperative preparation practices were relatively consistent between clinics in this study, while others were quite variable. Contact times with preoperative preparatory solutions for both patients and surgeons were often shorter than recommended. Evidence-based guidelines for these procedures in veterinary medicine should be established and implemented in order to help reduce preventable SSIs, while maintaining efficiency and cost-effectiveness.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Molecular Structure of [CuCl(L)]6; L= 2-(Methylamino)Pyridine

The 2-(methylamino) pyridine, L, reacts with CuCl in THF to give hexameric copper (I) complex, [CuCl(L)]6. The molecular structure has been determined by using single-crystal X-ray diffraction method. The complex crustallizes in the monoclinic space group P21/n with four molecules per unit cell. The unit cell dimensions are a = 8.3495 (15), b = 15.622 (6), and c = 17.0...

متن کامل

Measurement Properties of the Brief Pain Inventory- Short Form (BPI-SF) and the Revised Short McGill Pain Questionnaire-Version-2 (SF-MPQ-2) in Painrelated Musculoskeletal Conditions: A Systematic Review Protocol

The Brief Pain Inventory- Short Form (BPI-SF) and Revised Short-Form McGill Pain Questionnaire Version-2 (SFMPQ-2) are generic pain assessment tools used in research and practice for pain assessment in musculoskeletal(MSK) conditions. A comprehensive review that systematically analyses their measurement properties in MSKconditions has not been performed. This review protocol d...

متن کامل

Finite Sample Properties of Quantile Interrupted Time Series Analysis: A Simulation Study

Interrupted Time Series (ITS) analysis represents a powerful quasi-experime-ntal design in which a discontinuity is enforced at a specific intervention point in a time series, and separate regression functions are fitted before and after the intervention point. Segmented linear/quantile regression can be used in ITS designs to isolate intervention effects by estimating the sudden/level change (...

متن کامل

Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases

Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...

متن کامل

Preoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick

Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013