Elimination of high titre HIV from fibreoptic endoscopes

نویسنده

  • J Jeffries
چکیده

Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manualiy in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4*8X 104 to 3*5 X106 pg HIV antigenlml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde ali samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscopes and indicate that the use of dedicated equipment and long disinfection times

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of high titre HIV from fibreoptic endoscopes.

Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the k...

متن کامل

Antibiotic sensitivity of Pasteurella haemolytica isolated by means of a fibreoptic endoscope from cases of pneumonic pasteurellosis in cattle.

Bacterial isolations from tracheal and bronchial washes obtained with the aid of a fibreoptic endoscope were carried out over a 7 month period in a feedlot on calves suffering from acute pneumonic pasteurellosis. Pasteurella haemolytica and Pseudomonas aeruginosa represented the majority of isolates. Antibiotic sensitivities of the Pasteurella isolates are reported on.

متن کامل

New procedures. Improved technique for placement of intestinal feeding tube with the fibreoptic endoscope.

A feeding tube can be rapidly introduced into the small intestine through a makeshift 'external channel' of the fibreoptic endoscope. To prevent dislodgement of the feeding tube upon withdrawal of the endoscope, the former may be stabilized by means of the biopsy forceps introduced through its regular channel.

متن کامل

Effects of x-radiation on fibreoptic endoscopes.

Fibreoptic endoscopes exposed to x-radiation showed increased optical density of the fibre bundles with a reduction in light transmission. The length irradiated was important as well as the total dose, and there was a linear relationship between the dose/length product (Rm) and the loss of light transmission. The minimum light transmission acceptable for performing ERCP was found to be 57% of t...

متن کامل

Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde.

There is little information available on the bacteriological contamination of upper gastrointestinal fibreoptic endoscopes during routine use and the effects of 'disinfecting solutions'. A bacteriological evaluation was therefore made of cleaning an endoscope and its ancillary equipment with (1) water, (2) an aqueous solution of 1% cetrimide with 0.1% chlorhexidine, and (3) activated aqueous 2%...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006