Modeling and Testing of an Automobile AC Scroll Compressor, Part II: Model Validation
نویسندگان
چکیده
منابع مشابه
Modeling and Testing of an Automobile AC Scroll Compressor, Part I: Model Development
This paper presents the details of an overall simulation model that predicts the performance of an automobile air conditioning scroll compressor. Using the overall model, the compressor performance and discharge temperature can be predicted at specific operating conditions. The model will be used in the future to optimize the design of automobile air conditioning scroll compressors. The model w...
متن کاملRecent Developments and Advances in Automobile Space Conditioning Technology: A Review
Energy sector plays an important role in country’s economic development and it is going to be more significant in years to come. Managing this growing energy demand at reasonable cost therefore assumes national priority. A multidimensional approach is required keeping in view the various economic options available with effective demand management. Development towards the advances in automobile ...
متن کاملTesting and Validation of Simulation Tools of Hvac Mechanical Equipment including Their Control Strategies Part Iii: Validation of an Air-cooled Chiller Model
This paper presents a semi-empirical steady-state model of an air-cooled water chiller. The first part of the paper shows how the model is built by associating a scroll compressor and two heat exchanger sub-models. The second part of the paper presents the parameters identification process based on published manufacturer data (for the compressor and the whole chiller models). The only encounter...
متن کاملSimulation study on the performance of an Injection Scroll Compressor in a Heat Pump for Electric Vehicles
This paper presents the development and validation of a simulation model of an injection scroll compressor that can be used for optimization of a heat pump system for electric vehicles. The modeling considered the effects of refrigerant leakage and suction gas heating. The simulation model solved continuity and energy conservation equations using 4th Runge-Kutta scheme to predict the pressure a...
متن کاملDevelopment and testing of a multi-type air conditioner without using AC inverters
This paper reports the results from the development and performance testing of a cost effective, energy efficient, multi-type air conditioner that connected five indoor units (evaporators) to one outdoor unit (condenser) with a digital scroll compressor. Instead of using inverter technology, which has a potential risk of harmonic current emissions, this study used a digital scroll compressor, w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014