2D-3D Rigid Body Registration of X-ray Fluoroscopic and CT Images

نویسندگان

  • Lilla Zöllei
  • Eric Grimson
چکیده

Motivation: Although 2D images lack significant information that is present in 3D modalities, they might be conveniently and efficiently used to record details about the most current state of the imaged object. The most amount of information can be gained about the changes recorded by the 2D modalities and the detailed 3D model if we fuse the information provided by both of them. In order to achieve the proper spatial alignment of the different components, it is necessary to determine their relative position and orientation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral-based 2D/3D X-ray to CT image rigid registration

We present a spectral-based method for the 2D/3D rigid registration of X-ray images to a CT scan. The method uses a Fourier-based representation to decompose the six rigid transformation parameters problem into a twoparameter out-of-plane rotation and a four-parameter in-plane transformation problems. Preoperatively, a set of Digitally Reconstructed Radiographs (DRRs) are generated offline from...

متن کامل

Point Similarity Measures Based on MRF Modeling of Difference Images for Spline-Based 2D-3D Rigid Registration of X-Ray Fluoroscopy to CT Images

One of the main factors that affect the accuracy of intensity-based registration of two-dimensional (2D) X-ray fluoroscopy to three-dimensional (3D) CT data is the similarity measure, which is a criterion function that is used in the registration procedure for measuring the quality of image match. This paper presents a unifying framework for rationally deriving point similarity measures based o...

متن کامل

Fiducial Registration from a Single X-Ray Image: A New Technique for Fluoroscopic Guidance and Radiotherapy

Fiducial registration is useful both in applications where other registration techniques have poor performance and for validation of new registration techniques. Registration of 3D CT or MR images to 2D X-ray images is particularly difficult, in part because automated contour extraction from 2D images is not yet well solved and in part because of the considerable computational expense in matchi...

متن کامل

2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment

This study extends a previous research concerning intervertebral motion registration by means of 2D dynamic fluoroscopy to obtain a more comprehensive 3D description of vertebral kinematics. The problem of estimating the 3D rigid pose of a CT volume of a vertebra from its 2D X-ray fluoroscopy projection is addressed. 2D-3D registration is obtained maximising a measure of similarity between Digi...

متن کامل

Anatomical image-based rigid registration between fluoroscopic X-ray and CT: methods comparison and experimental results

This paper describes a practical, whole system approach to rigid registration between preoperative CT and intraoperative X-rays obtained with a tracked C-arm and demonstrates its efficacy experimentally. Our approach is generic, targeted to orthopaedic surgery, and includes fluoroscopic X-ray calibration, image distortion correction, optical tracking, and 2D/3D image registration. For 2D/3D ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001