Visualization of tensor fields using superquadric glyphs.

نویسندگان

  • Daniel B Ennis
  • Gordon Kindlman
  • Ignacio Rodriguez
  • Patrick A Helm
  • Elliot R McVeigh
چکیده

The spatially varying tensor fields that arise in magnetic resonance imaging are difficult to visualize due to the multivariate nature of the data. To improve the understanding of myocardial structure and function a family of objects called glyphs, derived from superquadric parametric functions, are used to create informative and intuitive visualizations of the tensor fields. The superquadric glyphs are used to visualize both diffusion and strain tensors obtained in canine myocardium. The eigensystem of each tensor defines the glyph shape and orientation. Superquadric functions provide a continuum of shapes across four distinct eigensystems (lambda(i), sorted eigenvalues), lambda(1) = lambda(2) = lambda(3) (spherical), lambda(1) < lambda(2) = lambda(3) (oblate), lambda(1) > lambda(2) = lambda(3) (prolate), and lambda(1) > lambda(2) > lambda(3) (cuboid). The superquadric glyphs are especially useful for identifying regions of anisotropic structure and function. Diffusion tensor renderings exhibit fiber angle trends and orthotropy (three distinct eigenvalues). Visualization of strain tensors with superquadric glyphs compactly exhibits radial thickening gradients, circumferential and longitudinal shortening, and torsion combined. The orthotropic nature of many biologic tissues and their DTMRI and strain data require visualization strategies that clearly exhibit the anisotropy of the data if it is to be interpreted properly. Superquadric glyphs improve the ability to distinguish fiber orientation and tissue orthotropy compared to ellipsoids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superquadric tensor glyphs

Tensor field visualization is a challenging task due in part to the multi-variate nature of individual tensor samples. Glyphs convey tensor variables by mapping the tensor eigenvectors and eigenvalues to the orientation and shape of a geometric primitive, such as a cuboid or ellipsoid. Though widespread, cuboids and ellipsoids have problems of asymmetry and visual ambiguity. Cuboids can display...

متن کامل

Visualizing Uncertainty in HARDI Tractography Using Superquadric Streamtubes

Standard streamtubes for the visualization of diffusion MRI data are rendered either with a circular or with an elliptic cross section whose aspect ratio indicates the relative magnitudes of the medium and minor eigenvalues. Inspired by superquadric tensor glyphs, we propose to render streamtubes with a superquadric cross section, which develops sharp edges to more clearly convey the orientatio...

متن کامل

Visualization and Analysis of Diffusion Tensor Fields

The power of medical imaging modalities to measure and characterize biological tissue is amplified by visualization and analysis methods that help researchers to see and understand the structures within their data. Diffusion tensor magnetic resonance imaging can measure microstructural properties of biological tissue, such as the coherent linear organization of white matter of the central nervo...

متن کامل

Investigation of myocardium structure of postinfarct porcine model using superquadric glyphs

Introduction Diffusion tensor imaging (DTI) has been demonstrated to be a powerful tool for assessment of myocardium at high spatial resolution. Several DTI studies were conducted to investigate infarcted left ventricular (LV) myocardium structure with focusing on myocardial fiber orientation, diffusivity or diffusion anisotropies [1-4]. However, more information remains to be elucidated, inclu...

متن کامل

T-flash: Tensor Visualization in Medical Studio

Tensor valued data are frequently used in medical imaging. For a 3-dimensional second order tensor such data imply at least six degrees of freedom for each voxel. The operators ability to perceive this information is of outmost importance and in many cases a limiting factor for the interpretation of the data. In this paper we propose a decomposition of such tensor fields using the Tflash tensor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2005