Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients1
نویسندگان
چکیده
OBJECTIVES to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue. METHOD this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds. RESULTS a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons); that is an average of 10.6 alarms per hour. CONCLUSION the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security.
منابع مشابه
Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
BACKGROUND Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step towar...
متن کاملChanges in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project.
BACKGROUND Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians' attitudes and practices toward clinical alarms and alarm fatigue are scarce. OBJECTIVE To examine if (1) a change i...
متن کاملClinical Alarms in Intensive Care Units: Perceived Obstacles of Alarm Management and Alarm Fatigue in Nurses.
OBJECTIVES The purpose of this descriptive study was to investigate the current situation of clinical alarms in intensive care unit (ICU), nurses' recognition of and fatigue in relation to clinical alarms, and obstacles in alarm management. METHODS Subjects were ICU nurses and devices from 48 critically ill patient cases. Data were collected through direct observation of alarm occurrence and ...
متن کاملBalancing the Tension Between Hyperoxia Prevention and Alarm Fatigue in the NICU.
BACKGROUND After the implementation of narrowed oxygen saturation alarms, alarm frequency increased in the C.S. Mott Children's Hospital NICU which could have a negative impact on patient safety. The Joint Commission on the Accreditation of Healthcare Organizations issued a Sentinel Event Alert for hospitals in 2013 to improve alarm safety, resulting in a 2014 National Patient Safety Goal requi...
متن کاملAttitudes and practices related to clinical alarms.
BACKGROUND The number of devices with alarms has multiplied in recent years, causing alarm fatigue in bedside clinicians. Alarm fatigue is now recognized as a critical safety issue. OBJECTIVE To determine if attitudes and practices related to clinical alarms have changed since 2005. METHODS The Healthcare Technology Foundation's Clinical Alarms Committee developed an online survey for hospi...
متن کاملذخیره در منابع من