Design of an integrating type neutron dose monitor.

نویسنده

  • Hirokuni Yamanishi
چکیده

It is intended that deuterium-deuterium reaction experiments will be performed for the next phase of the large helical device (LHD) at National Institute for Fusion Science (NIFS), Toki, Japan. To protect workers against radiation, the characteristics of the radiation field at the LHD workplace should be evaluated. The neutron fluence at the workplace was calculated by means of the radiation transportation code. Since the neutron energy distribution at the workplace has a wide energy range, from thermal to fast neutrons, a neutron dose monitor had to be especially designed. The author designed an integrating type neutron dose monitor for this purpose. Since this monitor has good responses for dose evaluation in every energy range, it should be able to evaluate the dose at the LHD workplace accurately.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of neutron effective dose from DD and DT neutron generators and the design of appropriate shield for standing user

Neutron Generators (NG) are used as a neutron source for different applications. During recent years, major efforts are underway to develop a high yield compact NG. In this way, radiation protection aspects need to be considered during the operation of these high yield NGs. In this paper the neutron effective dose of a NG operator has been calculated using MCNPX Monte Carlo code. The results sh...

متن کامل

A Novel Neutron Dosimeter

Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...

متن کامل

Passive neutron area monitor with CR39

Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...

متن کامل

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

Monitor units are not predictive of neutron dose for high-energy IMRT

BACKGROUND Due to the substantial increase in beam-on time of high energy intensity-modulated radiotherapy (>10 MV) techniques to deliver the same target dose compared to conventional treatment techniques, an increased dose of scatter radiation, including neutrons, is delivered to the patient. As a consequence, an increase in second malignancies may be expected in the future with the applicatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 146 1-3  شماره 

صفحات  -

تاریخ انتشار 2011