Transverse vs torsional ultrasound: prospective randomized contralaterally controlled study comparing two phacoemulsification-system handpieces

نویسندگان

  • Kerry K Assil
  • Lindsay Harris
  • Jeannie Cecka
چکیده

PURPOSE To compare surgical efficiency and multiple early clinical outcome variables in eyes undergoing phacoemulsification using either transversal or torsional ultrasound systems. SETTING Assil Eye Institute, Beverly Hills, CA, USA. DESIGN Prospective, randomized, clinician-masked, contralaterally controlled single-center evaluation. PATIENTS AND METHODS Patients seeking cataract removal in both eyes with implantation of multifocal intraocular lenses were randomly assigned to one of two treatment rooms for phacoemulsification with either a transverse ultrasound system or torsional handpiece system. The contralateral eye was treated at a later date with the alternate device. A total of 54 eyes of 27 patients having similar degrees of cataract, astigmatism, and visual potential were included. All operative data were collected for analysis, and patients were followed for 3 months after surgery. RESULTS Similar visual acuity was reported at all postoperative visits between the two groups. Mean phacoemulsification time and total power required were both significantly lower with the transverse system than with the torsional technique (P<0.05 for both). Similarly, mean total balanced salt solution used was significantly less with the transverse system vs torsional (P<0.05). Postoperative safety demonstrated significantly lower endothelial cell loss at 1 day and 1 month (P<0.05) with transverse vs torsional. Macular swelling was less at 1 week, 1 month, and 3 months with transverse vs torsional, although the difference did not achieve significance (P=0.1) at any single time point. Clinically detectable corneal edema was reported less frequently at all postoperative time points with the transverse system. CONCLUSION The transverse ultrasound system was found to be possibly associated with less balanced salt-solution use, less phacoemulsification time, and less power required than the torsional phaco system. Postoperative data suggested that improved phaco efficiency may translate to a better overall safety profile for the patient.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract

PURPOSE To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. SETTINGS Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. METHODOLOGY Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked cl...

متن کامل

Efficacy of Torsional Phaco in Hard Egyptian Cataract Versus Combined Torsional and Longitudinal Phaco Using the Infiniti Vision System

Purpose: To compare the efficacy and phacoemulsification parameters of torsional mode versus the combined torsional and longitudinal ultrasound mode in hard cataract of Egyptian patients. Methods: This randomized comparative study evaluated eyes 1, 7, and 30 days after phacoemulsification with an Infiniti Vision System using the torsional mode versus the combined torsional (100%) and longitudin...

متن کامل

Torsional ultrasound modality for hard nucleus phacoemulsification cataract extraction

AIM To evaluate the efficacy and safety of phacoemulsification using torsional modality with different parameter settings for hard nucleus cataract extraction. DESIGN A prospective, randomised clinical study. METHODS A clinical practice study conducted at the Cataract Service, Zhongshan Ophthalmic Center, Sun-Yat-Sen University, and Guangzhou. One eye each from 198 consecutive patients with...

متن کامل

Impact of intelligent phacoemulsification software on torsional phacoemulsification surgery

BACKGROUND The purpose of this study was to compare phacoemulsification energy parameters during torsional phacoemulsification with or without the use of intelligent phacoemulsification (IP) software. METHODS One hundred and twenty-eight eyes with nuclear grades ranging from 1 to 5 were enrolled in this randomized prospective study. Operated eyes were divided into two groups, ie, those operat...

متن کامل

Wound and surface temperatures in vivo in torsional and longitudinal modalities of ultrasound in coaxial microincisional cataract surgery

BACKGROUND To study phacoemulsification probe shaft/wound and corneal surface/tip temperatures in vivo during longitudinal, torsional and combined phacoemulsification modes and their relationship to machine parameters. DESIGN This was a prospective study at Chaithanya Eye Hospital and Research Institute, Trivandrum, India (tertiary). PARTICIPANTS Twenty-two eyes of 22 patients were randomiz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015