Comparison of Apical Extrusion of Debris by Using Single-File, Full-Sequence Rotary and Reciprocating Systems

نویسندگان

  • Maryam Ehsani
  • Robab Farhang
  • Azadeh Harandi
  • Saeid Tavanafar
  • Maryam Raoof
  • Saeedeh Galledar
چکیده

OBJECTIVES During root canal preparation, apical extrusion of debris can cause inflammation, flare-ups, and delayed healing. Therefore, instrumentation techniques that cause the least extrusion of debris are desirable. This study aimed to compare apical extrusion of debris by five single-file, full-sequence rotary and reciprocating systems. MATERIALS AND METHODS One hundred twenty human mandibular premolars with similar root lengths, apical diameters, and canal curvatures were selected and randomly assigned to six groups (n=20): Reciproc R25 (25, 0.08), WaveOne Primary (25, 0.08), OneShape (25, 0.06), F360 (25, 0.04), Neoniti A1 (25, 0.08), and ProTaper Universal. Instrumentation of the root canals was performed in accordance with the manufacturers' instructions. Each tooth's debris was collected in a pre-weighed vial. After drying the debris in an incubator, the mass was measured three times consecutively; the mean was then calculated. The preparation time by each system was also measured. For data analysis, one-way ANOVA and Games-Howell post hoc test were used. RESULTS The mean masses (±standard deviation) of the apical debris were as follows: 2.071±1.38mg (ProTaper Universal), 1.702±1.306mg (Neoniti A1), 1.295±0.839mg (OneShape), 1.109±0.676mg (WaveOne), 0.976±0.478mg (Reciproc) and 0.797±0.531mg (F360). Compared to ProTaper Universal, F360 generated significantly less debris (P=0.02). The ProTaper system required the longest preparation time (mean=88.6 seconds); the Reciproc (P=0.008), OneShape (P=0.006), and F360 (P=0.001) required significantly less time (P<0.05). CONCLUSIONS All instruments caused extrusion of debris through the apex. The F360 produced significantly less debris than did the ProTaper Universal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of apical and coronal extrusions using reciprocating and rotary instrumentation systems

BACKGROUND The aim of this study was to compare the apical and coronal extrusions by using two reciprocating and two rotary instrumentation systems. METHODS Eighty extracted human single-rooted anterior teeth were randomly assigned to four groups. Four different root canal instrumentation systems were used according to the manufacturers instructions, including two reciprocating single-file sy...

متن کامل

Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

INTRODUCTION The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. METHODS Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-...

متن کامل

Evaluation of Apical Extrusion of Debris and Irrigant Using Two New Reciprocating and One Continuous Rotation Single File Systems

OBJECTIVE Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation sy...

متن کامل

Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis

BACKGROUND All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. OBJECTIVES Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), an...

متن کامل

Evaluation of Apically Extruded Debris and Irrigant Produced by Different Nickel-Titanium Instrument Systems in Primary Teeth.

AIM The purpose of this study was to determine the amount of extruded debris and irrigant associated with different single-file systems and one multiple-file system. MATERIALS AND METHODS Forty-five newly extracted single rooted primary canine teeth were used in this study. The root canals were instrumented using the reciprocating single-file system, the single-file rotary system and the mult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2016