Ureteroscopic skills with and without Roboflex Avicenna in the K-box® simulator

نویسندگان

  • Silvia Proietti
  • Laurian Dragos
  • Esteban Emiliani
  • Salvatore Butticè
  • Michele Talso
  • Mohammed Baghdadi
  • Luca Villa
  • Steeve Doizi
  • Guido Giusti
  • Olivier Traxer
چکیده

INTRODUCTION The aim of this study was to evaluate the acquisition of basic ureteroscopic skills with and without Roboflex Avicenna by subjects with no prior surgical training. MATERIAL AND METHODS Ten medical students were divided in two groups: Group 1 was trained with Roboflex Avicenna and Group 2 with flexible ureteroscope alone, using the K-box® simulator model. Participants were scored on their ability to perform or not two exercises, recording the time. In addition, the participants were evaluated on the quality of their performance for the following parameters: respect of the surrounding environment, flow of the operation, orientation, vision centering and stability. RESULTS The first exercise was completed only by three and four out of five of students in Group 1 and Group 2, respectively. Stability with the scope was significantly more accurate in the first group compared with the second (P = 0.02). There were no differences in timing, flow or orientation between groups. Although not significant, a tendency of respecting the surrounding tissue and maintaining centered vision was perceived more in the first group. As for the second exercise, there were no differences between groups in regard of orientation, flow, respecting the surrounding tissue, stability or the ability of maintaining centered vision. Although not significant, the second group had a tendency of performing the exercise faster. CONCLUSIONS According to these preliminary results, the acquisition of basic ureteroscopic skills with and without robotic fURS in the K-box® simulator, by subjects with no prior surgical training, is similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new robot for flexible ureteroscopy: development and early clinical results (IDEAL stage 1-2b).

BACKGROUND An improved armamentarium has had a significant impact on the emerging role of flexible ureteroscopy (FURS) for the management of nephrolithiasis; however, FURS still represents a challenging technique. OBJECTIVE To examine a robotic device designed for FURS for its impact on ergonomics and outcome of the procedure based on the IDEAL (idea, development, evaluation, assessment, long...

متن کامل

Cl in ic al s tu di es First Romanian experience with Robotic ( Avicenna ) Flexible Ureteroscopy in Renal Stones

Introduction and Objectives. Roboflex Avicenna represents a new platform for flexible ureteroscopy, capable to provide a safer and more effective lithotripsy for renal calculi. Materials and methods. The study was prospective and included a number of 66 patients which underwent robotic flexible ureteroscopy (FURS) for renal calculi between July and December 2015. All the procedures were perform...

متن کامل

Highly Efficient Transfection of Dendritic Cells Derived from Esophageal Squamous Cell Carcinoma Patient: Optimization with Green Fluorescent Protein and Validation with Tumor RNA as a Tool for Immuno-genetherapy

This study was conducted to optimize a highly efficient mRNA transfection into dendritic cells (DC) derived from esophageal squamous cell carcinoma (ESCC) patients. Applying an electroporation technique, in vitro synthesized Green Fluorescent Protein (GFP) mRNA was transfected as an indicator into the DCs derived from a healthy donor. Flow cytometry revealed 84.9% transfection efficiency for DC...

متن کامل

Ureteroscopy and cystoscopy training: comparison between transparent and non-transparent simulators

BACKGROUND Simulators have been widely used to train operational skills in urology, how to improve its effectiveness deserves further investigation. In this paper, we evaluated training using a novel transparent anatomic simulator, an opaque model or no simulator training, with regard to post-training ureteroscopy and cystoscopy proficiency. METHODS Anatomically correct transparent and non-tr...

متن کامل

O16: Using Simulator to Measure the Skills of Taxi Drivers and Increasing the Safety of School Services Vehicles

In our country, Student transportations’ security and driving accidents statistics for students is one of the major concerns for relevant organizations such as educational organization. In current year, a system, was named Sepand, was formed in city taxi driver ::::::union:::::: by educational organization, NAJA traffic and city taxi driver ::::::union::::::. In this systems’ plan, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 70  شماره 

صفحات  -

تاریخ انتشار 2017