Differences between the estimated and Scheimpflug image-measured axial intraocular lens positions and their relation to refractive error after cataract surgery.
نویسندگان
چکیده
One of the main goals of cataract surgery is to achieve the planned postoperative refraction, thus minimizing the prediction error to prevent large refractive surprises. Uncertainty of the postoperative intraocular lens (IOL) position (described by postoperative anterior chamber depth [ACD]) is one of the unavoidable errors that arise when planning the diopter of the IOL. It can cause a postoperative refraction error of up to 0.75 diopter (D)1,2 and account for 22% to 38% of the refractive prediction error,3 depending on the axial length and formula used for the calculation.2 Our aim was to analyze the differences between preoperatively measured, postoperatively measured, and “formula-estimated ACDs” to assess the relationship between these differences and the postoperative subjective refractive error. The same type of SRK/T formula-calculated IOLs (Ar40e; Abbott Medical Optics, Inc., Santa Ana, CA) were implanted during cataract surgery in 102 eyes of 102 patients (age range: 36.2 to 87.5 years), with a target refraction of almost zero. Three photographs were taken with the Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany) to record the external ACD, which was repeated postoperatively for a minimum of 8 weeks. The visual acuity and refractive error were determined with a subjective visual acuity test. The subjective diopter deviation from the planned postoperative refractive outcome was identified as the “refraction error.” The difference between the postoperatively and preoperatively measured ACD was calculated in all cases. Next, we calculated the estimated ACD using the SRK/T formula, which we called the “formula-estimated ACD” (referring to effective lens position). We then subtracted the postoperatively measured ACD from the “formula-estimated ACD” and called it the “ACD estimation error.” The “ACD estimation error” had a median of -0.58 mm. The subjective refraction error was within ±0.25 D in 68.63% of cases and 0.25 or 0.5 D in 20.59% of cases. The differences between the different ACD values are presented in Bland–Altman graphs (Figure 1). The correlation between the axial length and preoperatively measured ACD was significant (r = 0.31, P < .001), as was the correlation between the axial length and preoperatively calculated “formula-estimated effective lens position” (r = 0.56, P < .001). The correlation was not significant between the axial length and the “ACD estimation error” (r = -0.12, P = .21) or between the “ACD estimation error” and the subjectively measured refraction error (r = 0.12, P = .26). The main reason for the unwanted refractive error after cataract surgery is the incorrect prediction of the postoperative axial position of the IOL.4 The main finding of our examinations is that the deviation from the “formula-estimated ACD” is large, whereas the range of the subjective residual refraction error is small. Moreover, we could not find any significant correlation between the “ACD estimation error” and this subjective refraction error. We concluded that the error involved in performing subjective refraction also
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملمقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت
Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...
متن کاملVisual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملAccuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.
PURPOSE To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). SETTING Jules Stein Eye Institute, David Geffen School of Medicine at University of Calif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of refractive surgery
دوره 30 8 شماره
صفحات -
تاریخ انتشار 2014