Field Map Reconstruction in Magnetic Resonance Imaging Using Bayesian Estimation

نویسندگان

  • Fabio Baselice
  • Giampaolo Ferraioli
  • Aymen Shabou
چکیده

Field inhomogeneities in Magnetic Resonance Imaging (MRI) can cause blur or image distortion as they produce off-resonance frequency at each voxel. These effects can be corrected if an accurate field map is available. Field maps can be estimated starting from the phase of multiple complex MRI data sets. In this paper we present a technique based on statistical estimation in order to reconstruct a field map exploiting two or more scans. The proposed approach implements a Bayesian estimator in conjunction with the Graph Cuts optimization method. The effectiveness of the method has been proven on simulated and real data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the quality of ultrasound images using Bayesian estimators

Medical ultrasound imaging due to close behavior of cancer tumors to body tissues has a low contrast. This problem with synthetic aperture imaging method has been addressed. Although the synthetic aperture imaging technique solved the low-contrast problem of ultrasound images, to an acceptable limit, but the performance of these methods is not even acceptable when the signal to noise ratio (SNR...

متن کامل

Iterative Off-resonance and Signal Decay Correction for Improved Multi-echo Imaging in MRI

Local deviations of the main field and signal decay due to transverse relaxation lead to perturbations of the Fourier encoding commonly applied in magnetic resonance imaging. Hence, images acquired with trajectories having long readout times suffer from artefacts such as blurring, geometric distortion, and intensity inhomogeneity. These effects can be corrected by means of iterative reconstruct...

متن کامل

The modeling of induced current density in eyes from static magnetic fields produce by MR scanner

Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...

متن کامل

Automatic HyperParameter Estimation in fMRI

Maximum a posteriori (MAP) in the scope of the Bayesian framework is a common criterion used in a large number of estimation and decision problems. In image reconstruction problems, typically, the image to be estimated is modeled as a Markov Random Fields (MRF) described by a Gibbs distribution. In this case, the Gibbs energy depends on a multiplicative coefficient, called hyperparameter, that ...

متن کامل

Interferometric image reconstruction as a nonlinear Bayesian estimation problem

This paper formulates interferometric image reconstriiction as a 2D absolute phase estimation problem The original phase image is modeled as a sample of a Gauss Markov random field; the observations are the noisy in-phase (cosine) and quadrature (sine) images. The proposed solution combines features of the iterated conditional modes algorithm with nonlinear stochastic absolute phase estimation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -