Commissioning of the Heidelberg Cryogenic Trap for Fast Ion Beams (ctf)

نویسندگان

  • M. Lange
  • K. Blaum
  • M. Froese
  • M. Grieser
  • D. Kaiser
  • S. Menk
  • D. A. Orlov
  • A. Shornikov
  • T. Sieber
  • J. Varju
  • R. von Hahn
چکیده

We report on the present state of commissioning of the cryogenic electrostatic trap for fast ion beams (CTF) at the Max-Planck-Institut für Kernphysik in Heidelberg. The device has recently passed a cryogenic test, during which the trap was cooled down by 1.8 K superfluid helium. No leaks of the helium supply system were observed, the temperature below 10 K was reached, and the required position stability of the trap electrodes was confirmed over the investigated temperature range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linac Commissioning for the Heavy Ion Cancer Therapy Facility HIT

The accelerator part of the clinical facility for cancer therapy HIT using energetic proton and ion beams (C, He and O) has been installed during 2006 at the Radiologische Universitätsklinik in Heidelberg, Germany [1]. The commissioning of the injector linac was performed in three steps for the LEBT, the RFQ and the IH-DTL and has successfully ended in December 2006. Some major results are brie...

متن کامل

Physics with colder molecular ions: The Heidelberg Cryogenic Storage Ring CSR

A novel cryogenic electrostatic storage ring is planned to be built at the Max-Planck Institute for Nuclear Physics in Heidelberg. The machine is expected to operate at low temperatures (∼ 2 K) and to store beams with kinetic energies between 20 to 300 keV. An electron target based on cooled photocathode technology will serve as a major tool for the study of reactions between molecular ions and...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Cryogenic ion trapping systems with surface-electrode traps.

We present two simple cryogenic rf ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 h. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008