Image quality in reduced-dose coronary CT angiography.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES Concerns for patient's risk of radiation-induced cancer have increased demand for reduced-dose coronary computed tomography angiography (CCTA). Previous comparisons of full and reduced-dose CCTA were not conclusive, because results were compared in different groups of patients. Presented here are results in patients examined by a widely used full dose CCTA protocol and a new low-dose alternative. MATERIALS AND METHODS Standard full-dose and low-dose CCTA with tube voltages of 120/100 kV were applied on 70 patients with intermediate probability of coronary artery disease (CAD). Both protocols used prospective electrocardiogram-gated acquisition on a 320-detector row CT scanner, whereas at low-dose CCTA the phase window was increased from 10% to 75% of R-R interval. RESULTS Despite a mean dose reduction of 80%, from 4.9 ± 0.98 to 0.98 ± 0.24 mSv, visual image quality was not significantly affected at the low-dose protocol. Contrast level, image noise, and CNR for both protocols were similar in the majority of coronary segments. CNR for standard and low-dose protocol were 23.7 ± 17.1 and 23.2 ± 26.8, P = NS. Correlation between visual image quality and heart rate variability was strong at low dose: r = -0.58, P = .01, and absent at full dose: r = -0.07, P = .77. CONCLUSION Image quality of blood vasculature is generally not affected by 80% CCTA dose reduction applied to standard prospective electrocardiogram-gated acquisition. The performance at the low-dose protocol owes to the increased phase window, enhancing image quality at the cost of sensitivity to heart rate variability as compared with standard CCTA.
منابع مشابه
Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...
متن کاملProspective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...
متن کاملProspectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.
PURPOSE To retrospectively compare image quality, radiation dose, and blood vessel assessability for coronary artery computed tomographic (CT) angiograms obtained with a prospectively gated transverse (PGT) CT technique and a retrospectively gated helical (RGH) CT technique. MATERIALS AND METHODS This HIPAA-compliant study received a waiver for approval from the institutional review board, in...
متن کاملBreast Radiation Protection in Coronary Angiography
Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...
متن کاملComparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملCoronary artery bypass grafts: ECG-gated multi-detector row CT angiography--influence of image reconstruction interval on graft visibility.
PURPOSE To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Academic radiology
دوره 18 8 شماره
صفحات -
تاریخ انتشار 2011