A fully automated liquid–liquid extraction system utilizing interface detection

نویسندگان

  • Eugene Maslana
  • Robert Schmitt
  • Jeffrey Pan
چکیده

The development of the Abbott Liquid-Liquid Extraction Station was a result of the need for an automated system to perform aqueous extraction on large sets of newly synthesized organic compounds used for drug discovery. The system utilizes a cylindrical laboratory robot to shuttle sample vials between two loading racks, two identical extraction stations, and a centrifuge. Extraction is performed by detecting the phase interface (by difference in refractive index) of the moving column of fluid drawn from the bottom of each vial containing a biphasic mixture. The integration of interface detection with fluid extraction maximizes sample throughput. Abbott-developed electronics process the detector signals. Sample mixing is performed by high-speed solvent injection. Centrifuging of the samples reduces interface emulsions. Operating software permits the user to program wash protocols with any one of six solvents per wash cycle with as many cycle repeats as necessary. Station capacity is eighty, 15 ml vials. This system has proven successful with a broad spectrum of both ethyl acetate and methylene chloride based chemistries. The development and characterization of this automated extraction system will be presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Automatic semi-microcolumn liquid chromatographic determination of catecholamines in rat plasma utilizing peroxyoxalate chemiluminescence reaction.

A fully automated and highly sensitive method with a semi-microcolumn liquid chromatography system for the determination of rat plasma catecholamines (CAs) was developed. Automated on-line extraction of CAs in diluted plasma using a precolumn packed with strong acidic cation exchange resin was coupled with separation of CAs on a semi-microcolumn (250 x 1.5 mm id). fluorogenic derivatization wit...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Phenol and Carvacrol in Honey Samples Using Dispersive Liquid-Liquid Microextraction and Experimental Design for Optimization

A very simple, rapid and sensitive dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography and flame ionization detection (GC-FID) was developed for the determination of phenol and carvacrol in honey samples. A mixture of 100 µl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. Thereby a cloudy sol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2000