Sirolimus-eluting stent treatment at high-volume centers confers lower mortality at 6-month follow-up: results from the prospective multicenter German Cypher Registry.

نویسندگان

  • Ahmed A Khattab
  • Christian W Hamm
  • Jochen Senges
  • Ralph Toelg
  • Volker Geist
  • Tassilo Bonzel
  • Malte Kelm
  • Benny Levenson
  • Christoph A Nienaber
  • Thomas Pfannebecker
  • Georg Sabin
  • Steffen Schneider
  • Ulrich Tebbe
  • Franz-Josef Neumann
  • Gert Richardt
چکیده

BACKGROUND Studies continue to identify percutaneous coronary intervention procedural volume both at the institutional level and at the operator level as being strongly correlated with outcome. High-volume centers have been defined as those that perform >400 percutaneous coronary intervention procedures per year. The relationship between drug-eluting stent procedural volume and outcome is unknown. We investigated this relationship in the German Cypher Registry. METHODS AND RESULTS The present analysis included 8201 patients treated with sirolimus-eluting stents between April 2002 and September 2005 in 51 centers. Centers that recruited >400 sirolimus-eluting stent patients in this time period were considered high-volume centers; those with 150 to 400 patients were considered intermediate-volume centers; and those with <150 patients were designated as low-volume centers. The primary end point was all death, myocardial infarction, and target-vessel revascularization at 6 months. This end point occurred in 11.3%, 12.1%, and 9.0% of patients in the low-, intermediate-, and high-volume center groups, respectively (P=0.0001). There was no difference between groups in the rate of target-vessel revascularization (P=0.2) or cerebrovascular accidents (P=0.5). The difference in death/myocardial infarction remained significant after adjustment for baseline factors (odds ratio 1.85, 95% confidence interval 1.31 to 2.59, P<0.001 for low-volume centers; odds ratio 1.69, 95% confidence interval 1.29 to 2.21, P<0.001 for intermediate-volume centers). Patient and lesion selection, procedural features, and postprocedural medications differed significantly between groups. CONCLUSIONS The volume of sirolimus-eluting stent procedures performed on an institutional level was inversely related to death and myocardial infarction but not to target-vessel revascularization at 6-month follow-up. Safety issues are better considered in high-volume centers. These findings have important public health policy implications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical outcomes after sirolimus-eluting, paclitaxel-eluting, and bare metal stents (from the first phase of the prospective multicenter German DES.DE Registry).

The prospective multicenter German Drug-Eluting Stent (DES.DE) registry is an observational study to analyze and evaluate the therapeutic principle of the differential drug-eluting stents (sirolimus- and paclitaxel-eluting stents) and bare metal stents under real world conditions in the context of the German healthcare system. The baseline clinical and angiographic characteristics and follow-up...

متن کامل

Safety and efficacy of biodegradable polymer-coated sirolimus-eluting stents in "real-world" practice: 18-month clinical and 9-month angiographic outcomes.

OBJECTIVES This study sought to evaluate the safety and efficacy of a biodegradable polymer-coated sirolimus-eluting stent (Excel, JW Medical System, Weihai, China) with 6-month dual antiplatelet therapy in daily practice. BACKGROUND It has been hypothesized that persistent presence of polymer may compromise the safety of drug-eluting stents, and that therefore biodegradable polymer coatings ...

متن کامل

Three-year outcomes after sirolimus-eluting stent implantation for unprotected left main coronary artery disease: insights from the j-Cypher registry.

BACKGROUND Long-term outcomes after stenting of an unprotected left main coronary artery (ULMCA) with drug-eluting stents have not been addressed adequately despite the growing popularity of this procedure. METHODS AND RESULTS j-Cypher is a multicenter prospective registry of consecutive patients undergoing sirolimus-eluting stent implantation in Japan. Among 12 824 patients enrolled in the j...

متن کامل

Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases.

BACKGROUND The Firebird 2(TM) sirolimus-eluting stent (Firebird 2 stent) is a second-generation sirolimus-eluting stent which has a cobalt-chromium alloy stent platform, a brand new bracket structure, and two layers of styrene-butylenes-styrene polymer coatings with better biocompatibility. The Firebird 2(TM) cObalt-Chromium alloy sirolimus-elUting Stent registry (FOCUS registry) aimed to evalu...

متن کامل

Comparison of 5-year outcomes in patients with and without unprotected left main coronary artery disease after treatment with sirolimus-eluting stents: insights from the j-Cypher registry.

OBJECTIVES This study assessed 5-year outcomes after implantation of sirolimus-eluting stents (SES) for unprotected left main coronary artery (ULMCA) disease in comparison with that for non-left main disease. BACKGROUND More information on long-term outcomes after ULMCA stenting is needed. METHODS The j-Cypher is a multicenter prospective registry of consecutive patients undergoing SES impl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 120 7  شماره 

صفحات  -

تاریخ انتشار 2009