Intraventricular CSF pulsation artifact on fast fluid-attenuated inversion-recovery MR images: analysis of 100 consecutive normal studies.

نویسندگان

  • R Bakshi
  • S D Caruthers
  • V Janardhan
  • M Wasay
چکیده

BACKGROUND AND PURPOSE CSF pulsation artifact is a pitfall of fast fluid-attenuated inversion-recovery (FLAIR) brain MR imaging. We studied ventricular CSF pulsation artifact (VCSFA) on axial FLAIR images and its relationship to age and ventricular size. METHODS Fast FLAIR axial images were obtained on a 1.5-T unit (8000/150/2 [TR/TE/ excitations], inversion time = 2200, field of view = 24 cm, matrix = 189x256, and 5-mm interleaved sections). Two observers rated VCSFA (hyperintensity on FLAIR images) in the lateral, third, and fourth ventricles by using a three-point ordinal scale in 100 consecutive subjects (ages 20-86 years) with normal brain MR studies. Left-to-right third ventricular width was also measured. RESULTS Seventy-two subjects had VCSFA in at least one ventricular cavity. The fourth ventricle was the most common site of VCSFA (n = 58), followed by the third ventricle (n = 47) and the lateral ventricles (n = 13). VCSFA was usually severe in the third and fourth ventricles and less severe in the lateral ventricles. Fourth ventricular VCSFA was significantly associated with third ventricular VCSFA. Increasing third ventricular size and, to a lesser extent, increasing age was significantly associated with VCSFA. Ghost pulsation of VCSFA occurred across the brain parenchyma in the phase-encoding direction. VCSFA seen in the fourth ventricle on axial FLAIR images disappeared on sagittal FLAIR images in one subject. CONCLUSION VCSFA on axial FLAIR images represents inflow artifact caused by inversion delay and ghosting effects. VCSFA might obscure or mimic intraventricular lesions, especially in the third and fourth ventricles. Although common in adults of all ages, VCSFA is associated with advancing age and increasing ventricular size. Thus, altered CSF flow dynamics that occur with ventriculomegaly and aging contribute to VCSFA on axial FLAIR MR images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperintense signal abnormality in subarachnoid spaces and basal cisterns on MR images of children anesthetized with propofol: new fluid-attenuated inversion recovery finding.

BACKGROUND AND PURPOSE MR imaging is the method of choice for pediatric neuroimaging. Sedation is often needed to suppress patient motion and ensure diagnostic image quality, and propofol is rapidly becoming the preferred anesthetic. The purpose of this study was to document a new finding on fast fluid-attenuated inversion recovery (fast-FLAIR) MR images of children anesthetized with propofol t...

متن کامل

Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.

BACKGROUND AND PURPOSE Single-shot, fast spin-echo, fluid attenuated inversion recovery (SS-FSE-FLAIR) images are frequently used to detect disease in the brain and subarachnoid space in confused or uncooperative patients who may move during the examination. In some of these patients, high signal intensity areas are seen on good-quality images in the subarachnoid space and ventricular system in...

متن کامل

The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.

PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...

متن کامل

Applicability and advantages of flow artifact-insensitive fluid-attenuated inversion-recovery MR sequences for imaging the posterior fossa.

We describe a new sequence, flow artifact-insensitive fluid-attenuated inversion recovery (FAIS-FLAIR), that capitalizes on the advantages of fluid-attenuated inversion recovery (FLAIR) while minimizing FLAIR-related artifacts such as those often encountered in the posterior fossa. Twenty-eight patients with posterior fossa disease underwent FAIS-FLAIR, conventional FLAIR, and spin-echo MR stud...

متن کامل

Analysis of elements in a minimal amount of temporomandibular joint fluid on fluid-attenuated inversion recovery magnetic resonance images.

OBJECTIVE The aim of this study was to elucidate possible elements in minimal amounts of fluid (MF) in the temporomandibular joint by analyzing signal intensities in T2-weighted and fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) images. STUDY DESIGN Fifteen joints (15 patients) with MF were subjected to MR imaging to obtain T2-weighted and FLAIR images. Regions of interes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2000