Measurement and Imaging of Planar Electromagnetic Phantoms Based on NMR Imaging Methods
نویسندگان
چکیده
Planar electromagnetic phantom design for measurement and imaging using NMR has been performed. Electromagnetic phantom computation and testing on a NMR 0.178 Tesla Esaote Opera imager were accomplished. The classical geometrical and chemical phantoms are generally used for testing of NMR imaging systems. They are simple cylindrical or rectangular objects with different dimensions and shapes with holes filled with specially prepared water solutions. In our experiments a homogeneous phantom (reference medium) a container filled with water was used. The resultant image represents the magnetic field distribution in the homogeneous phantom. An image acquired by this method is actually a projection of the sample properties onto the homogeneous phantom. The goal of the paper is to map and image the magnetic field deformation using NMR imaging methods. We are using a double slender rectangular vessel with constant thickness filled with specially prepared water solution in our experiments. For detection a carefully tailored gradient-echo imaging method, susceptible to magnetic field homogeneity, was used.
منابع مشابه
Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging
Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...
متن کاملDesign and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملSensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging
Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...
متن کاملDetermination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera
Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution. The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...
متن کاملQuantification of partial volume effects in planar imaging
Introduction: The limited resolution of the imaging system causes partial volume effects (PVEs). These results in spreading of image counts to the neighboring pixels. This phenomenon is called spill-out effect. This study aimed at quantifying PVEs using ImageJ. Methods:Technetium-99m solution of concentration of 74 kBq/ml was filled into spheres A, B<...