Our study focuses on the development of a new feature driven speech-processing strategy for cochlear implant system. In each cycle of stimulation of the cochlea, an electrode, corresponding to second formant frequency was chosen among 14 basilar electrodes. On the base of voiced/unvoiced decision of the speech, an electrode corresponding to first formant frequency was selected for stimulation among 6 apex electrodes. Additionally 4-6 electrodes were chosen for stimulation by maxima energy criteria. Speech intelligibility tests on multi syllable Japanese words within normal hearing listeners by acoustic simulation were provided to evaluate performance of the proposed strategy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Traveling wave based group delays for cochlear implant speech processing

Cochlear implant speech processors seek to generate a neural response that mimics normal hearing. However, the cochlear phase response is generally discarded, together with other fine scale temporal aspects of sound. We sought to incorporate and compare a variety of cochlear traveling wave delays (i.e. group delays) in a clinical speech processing strategy. Traveling wave delays resulted in a s...

متن کامل

Using a Personal Computer to Perform Real-Time Signal Processing in Cochlear Implant Research

Cochlear implants are electronic devices that have enabled individuals with severe to profound hearing losses to regain some hearing. There is, however, substantial variability in speech perception performance among users of cochlear implants. One factor that may contribute to the individual differences is the way in which the device converts acoustic sound waves into electrical stimulation: th...

متن کامل

Simulated phase-locking stimulation: an improved speech processing strategy for cochlear implants.

The continuous interleaved sampling (CIS) speech-processing strategy has been widely used for cochlear implants to extract speech envelope information without preserving phase information. In this study, a novel simulated phase-locking stimulation (SPLS) strategy, which detects zero-crossing times of the narrow-band signal of each band, was developed to extract both phase and amplitude-envelope...

متن کامل

Speech Processing Strategies for Cochlear Prostheses-the Past, Present and Future: a Tutorial Review

Cochlear Implants are widely accepted prosthetic devices that improve the hearing ability of people with profound hearing loss. The cochlear implant speech processor is responsible for decomposing the input sound into different frequency bands and delivering the most appropriate pattern to the electrodes. The performance of the cochlear prostheses depends on various parameters such as number of...

متن کامل

High Performance Programmable Bi-phasic Pulse Generator Design for a Cochlear Speech Processor

Cochlear implant devices are designed to provide sound sensation and improved speech understanding to people who are profoundly hearing impaired. Best speech recognition could be achieved by using multi-channel, multi-electrode cochlear implant devices. In a multichannel cochlear prosthesis, channel interaction and tissue damage are important issues to be solved. Speech processing and modidatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001