Effects of temporal frequency on phase-dependent sensitivity to heterochromatic flicker.

نویسندگان

  • W H Swanson
  • J Pokorny
  • V C Smith
چکیده

Modulation sensitivity was measured as a function of the relative phase of two equiluminous chromatic sources (564 and 625 nm) for temporal frequencies ranging from 1 to 40 Hz. Measurements were made at a retinal illuminance of 900 Td, with a 2 degree field metameric to approximately 600 nm. For most frequencies, the phase of least sensitivity was other than 180 degrees, indicating the existence of a luminance response to antiphase modulation. Additional data sets examined the effects of field size (0.5 degrees-8 degrees) and mean chromaticity (583-610 nm). Variation in field size, chromaticity, and photometric setting had little effect on the phase of least sensitivity. The data were fitted by using vector summation between luminance and chromatic responses; the modulation-sensitivity functions that resulted from this analysis agreed with those of earlier studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of chromatic adaptation on phase-dependent sensitivity to heterochromatic flicker.

Temporal modulation sensitivity was measured as a function of the relative phase of two equiluminous chromatic sources (564 and 625 nm) for temporal frequencies from 6 to 20 Hz. The difference between 180 degrees and the phase of least sensitivity was computed as the measured phase shift. A 2 degree test field was superimposed upon 8 degrees chromatic adapting fields with luminances from 100 to...

متن کامل

Chromatic adaptation alters spectral sensitivity at high temporal frequencies.

To evaluate the effects of chromatic adaptation on spectral sensitivity at temporal frequencies within the region of high-frequency linearity, critical flicker frequency was measured as a function of red-green luminance ratio for counterphase flicker of 649- and 555-nm light. For eight observers, the relative weight of the contribution of the long-wavelength-sensitive cones to flicker detection...

متن کامل

Amplitude and phase of responses of macaque retinal ganglion cells to flickering stimuli.

1. We have measured responses of macaque retinal ganglion cells to a uniform flickering field, with variation in luminance, chromaticity or both (heterochromatic flicker). 2. With heterochromatic flicker, as the luminance ratio of the flicker components was varied, phasic ganglion cell activity went through a minimum and an abrupt phase change close to equal luminance. Tonic ganglion cell respo...

متن کامل

Heterochromatic modulation photometry.

Heterochromatic modulation photometry is a method for obtaining equiluminance for a pair of heterochromatic lights presented in temporal alternation. A series of fixed standard luminance/test luminance ratios are presented, and at each ratio the modulation depth of the pair is reduced in tandem until the observer reports that flicker disappears. The data can be described by a luminance contrast...

متن کامل

Flicker brightness enhancement and visual nonlinearity

The purpose of this study was to investigate the nonlinear mechanism underlying brightness enhancement, in which a flickering stimulus appears brighter than a steady stimulus of equal mean luminance. The flickering and matching stimuli were temporally alternated. Both were cosine windowed to minimize the potential effects of temporal transients. Subjects adjusted the amplitude of the matching s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics and image science

دوره 4 12  شماره 

صفحات  -

تاریخ انتشار 1987