SU-E-T-495: Monte Carlo Dose Verification of Passive Scattering Proton Therapy for Prostate Cancer.

نویسندگان

  • D Giantsoudi
  • H Paganetti
چکیده

PURPOSE To verify the clinical pencil beam dose calculation algorithm for passive scattering proton therapy using field with large range in tissue, i.e. in prostate cancer, using a Monte Carlo (MC) simulation system. METHODS Previously treated prostate cancer cases were randomly selected from our patient database. All patients received the same dose prescription of 50Gy (25 fractions) to planning treatment volume including the seminal vesicles (PTV1), followed by 28Gy (14 fractions) boost to the prostate gland only (PTV2). Patient and beam geometry were imported to our MC simulation platform (TOPAS - TOol for PArticle Simulation) and the dose of each individual beam, as well as their weighted sum, were calculated and compared to pencil beam algorithm-based calculation from the clinical treatment planning system (XiO). RESULTS Preliminary results from four patient cases show overall good agreement between the pencil beam and MC calculations. However, a small but systematic overestimation of the dose, as calculated by the pencil beam calculation algorithm, was noticed for the target structures (<2% difference in D95 for PTV1 and PTV2), compared to the MC calculation. The inverse was observed for the OARs (rectum and bladder) for which the dose seems to be somewhat underestimated by the pencil beam calculation algorithm (up to 3.75% difference in the volume covered by the 70Gy and 75Gy isodose lines). Furthermore, systematic difference in the range calculation was noticed: the pencil beam calculation algorithm results in larger proton range, in the order of 3-4mm, compared to the MC calculations for all beams and patients studied. This can be attributed to the bone anatomy in the path of the beams (femoral heads). CONCLUSIONS Routine MC dose calculation has the potential to improve delivery accuracy in proton therapy of prostate cancer and influence the analysis of currently ongoing clinical trials of protons versus IMRT. Funded by NIH/NCI R01 CA140735.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy

Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...

متن کامل

Monte Carlo calculations of dose distribution for the treatment of gastric cancer with proton therapy

Proton therapy is a common form of external radiation therapy based on the manipulation of Bragg peak of this beam, it can treat the tumor by delivering high levels of doses to it, while protecting surrounding healthy tissues against radiation. In this work, the dose distribution of proton and secondary particles such as neutrons, photons, electrons and positrons in gastric cancer proton therap...

متن کامل

Evaluation of the effective dose during PBFT for brain cancer: A Monte Carlo Study

Introduction: Recently, an approach exploiting the proton therapy biological enhancement by using Boron atoms injected inside a tumor, has been proposed. Three alpha particles with an average energy around 4MeV are emitted from the point of reaction between a proton and boron. In addition, the 719 keV prompt gamma emitted by the proton Boron fusion reactions can be used for on-...

متن کامل

A comparison of arrived dose to the heart in the treatment of breast cancer in different modes of proton radiation by proton therapy using Monte Carlo simulation

Introdution: Today, the Advantages of radiation therapy by charged particles is indicated for the treatment of cancerous. During the passing of proton beam in the body tissues, secondary particles produce, which penetrate to the body healthy tissues and cause damage. The aim of this research was calculating the Spread out Bragg Peak for covering the breast cancer and investigating arrived dose ...

متن کامل

SU-E-T-289: Scintillating Fiber Based In-Vivo Dose Monitoring System to the Rectum in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation.

PURPOSE To construct a dose monitoring system based on an endorectal balloon coupled to thin scintillating fibers to study the dose delivered to the rectum during prostate cancer proton therapy METHODS: The Geant4 Monte Carlo toolkit version 9.6p02 was used to simulate prostate cancer proton therapy treatments of an endorectal balloon (for immobilization of a 2.9 cm diameter prostate gland) and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012