Quantitative studies of microcirculatory structure and function. III. Microvascular hemodynamics of cat mesentery and rabbit omentum.

نویسندگان

  • B W Zweifach
  • H H Lipowsky
چکیده

We made simultaneous measurements of intravascular pressure and red blood cell velocity for vessels which make up the modular configuration of microvascular networks in mesentery and omentum. An analysis of these variables and the computed volumetric flow rates is presented for arterioles which had a maximum diameter of 56 micrometer through the "true capillaries" (typically 7 micrometer for mesentery and 8 micrometer for omentum) to 56-micrometer venules. The spatial variance of pressure and flow is related to topographical features of each network. Vascularization statistics for each network are presented and demonstrate a unique ratio of potential microvascular exchange area to module planar area, with values of 0.71 +/- 0.22 (SD) for omentum and 0.19 "/- 0.03 (SD) for mesentery. Analysis of the volumetric flow rate for each module demonstrates a linear relationship to the planar area of tissue serviced by each modular network. In situ perfusion rates of 1180 ml/min per 100 g and 105 ml/min per 100 g were determined for omentum and mesentery, respectively. The hemodynamic resistance of the omental and mesenteric circuitry was evaluated, and in the case of the omentum, found to be inversely proportional to the planar area of the module. The arterial to venous distribution of pressure and flow for the mosaic of contiguous modules in omentum and mesentery is described and related to the deployment of parallel and serial microvessels of each network.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Network model of pulsatile hemodynamics in the microcirculation of the rabbit omentum.

GROSS, JOSEPH F., MARCOS INTAGLIETTA, AND BENJAMIN W. ZWEIFACH. Network model of pulsatile lzemodynamics in the microcirculation of the rabbit omentum. Am. J. Physiol. 226(5) : 1117-l 123. 1974.-Pulsatile pressure and red cell velocities were measured throughout the microvasculature of the rabbit omentum as a function of the order of branching. The data were analyzed in terms of a network model...

متن کامل

Quantitative studies of microcirculatory structure and function. II. Direct measurement of capillary pressure in splanchnic mesenteric vessels.

A systematic study was made of capillary pressures in the microvascular bed of the mesentery of the cat. Simultaneous recordings were made with two micropipettes using a modification of the Wiederhielm servo-null system. All of the measurements were then referred to their specific location in the capillary bed by photographically reconstructing discrete networks. Pressures in different capillar...

متن کامل

Isolated Peritoneal, Mesenteric, and Omental Hydatid Cyst: A Clinicopathologic Narrative Review

Hydatid disease (HD) is caused by Echinococcus granulosus and is endemic in many parts of the world. This parasitic tapeworm can produce cysts in almost every organ of the body, with the liver and lung being the most frequently targeted organs. Peritoneum, omentum, and mesentery are among these unusual locations, which can cause diagnostic challenge and treatment delay. This review provides inf...

متن کامل

Hematocrit distribution and tissue oxygenation in large microcirculatory networks.

OBJECTIVE Oxygen tension in the brain is controlled by the microcirculatory supply of RBC, but the effect of non-Newtonian blood flow rheology on tissue oxygenation is not well characterized. This study assesses different biphasic blood flow models for predicting tissue oxygen tension as a function of microcirculatory hemodynamics. METHODS Two existing plasma-skimming laws are compared agains...

متن کامل

Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic

Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 1977