Comparison of Transcutaneous and Capillary Measurement of PCO2 in Hypercapnic Subjects.

نویسندگان

  • Sven Stieglitz
  • Sandhya Matthes
  • Christina Priegnitz
  • Lars Hagmeyer
  • Winfried Randerath
چکیده

BACKGROUND Measurement of PCO2 is vital in determining effective alveolar ventilation. However, obtaining capillary PCO2 by a skin prick of the earlobe is painful, and nocturnal measurements disturb sleep. End-expiratory measurement of PCO2 is also well established, but there is a low precision in predicting arterial or capillary CO2. The purpose of the study was to evaluate nocturnal measurement of noninvasive, transcutaneous PCO2 (PtcCO2 ) measurement in hypercapnic subjects. METHODS In this prospective study, 31 subjects with chronic hypercapnic failure--in a stable phase of the underlying disease--and a control group of 12 healthy volunteers were included. Transcutaneous measurements were taken by the Tosca sensor (Radiometer, Copenhagen, Denmark) over a period of at least 6 h during the night. A capillary blood gas was measured at midnight and 4:00 am. RESULTS The mean nocturnal capillary PCO2 (PcapCO2 ) of subjects was 50.6 ± 10.2 mm Hg. In the 31 subjects with known hypercapnic respiratory failure, the correlation between PtcCO2 and PcapCO2 at midnight was 0.86 and at 4:00 am r = 0.80. The bias of the hypercapnic subjects was d = + 4.5 with a limit(s) of agreement of 2 SD = 13.0. The process of blood sampling caused no significant change in PtcCO2 . CONCLUSIONS Our study evaluated transcutaneous capnography as a continuous nocturnal measurement in hypercapnic subjects. We found a good agreement between the methods. Because CO2 is not constant in patients with respiratory failure, but instead fluctuates, we would recommend the continuous transcutaneous measurement of PCO2 as our method of choice in the diagnosis of nocturnal hypercapnia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What is the potential role of transcutaneous carbon dioxide in guiding acute noninvasive ventilation?

BACKGROUND Transcutaneous carbon dioxide (PtcCO2 ) monitoring is rarely used in the acute hospital setting, where serial samples of arterial blood are instead taken to measure carbon dioxide tension (PaCO2 ). In this pilot observational study, we assessed the potential of PtcCO2 monitoring to calculate pH and guide management of acute noninvasive ventilation (NIV). METHODS Ten subjects with a...

متن کامل

Assessing Initial Response to High-Frequency Jet Ventilation in Premature Infants With Hypercapnic Respiratory Failure.

BACKGROUND High-frequency jet ventilation (HFJV) has been used in conjunction with conventional ventilation for infants with respiratory failure. We sought to identify parameters that were associated with successful application of HFJV in patients with hypercapnic respiratory failure. METHODS A single-center, retrospective review of infants who received HFJV was conducted. Subjects were enrol...

متن کامل

Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults.

Transcutaneous carbon dioxide and oxygen tensions (tc-pCO2 and tc-pO2) were measured in seven healthy adult volunteers during hyperventilation in atmospheric air and during CO2 inhalation. Three skin sensors were applied to each subject: an O2 electrode, a CO2 electrode, and a combined O2-CO2 electrode, each heated to 44 degrees C. We observed close correlation between tc-pCO2 and capillary-pCO...

متن کامل

Early Effectiveness of Noninvasive Positive Pressure Ventilation on Right Ventricular Function in Chronic Obstructive Pulmonary Disease Subjects with Acute Hypercapnic Respiratory Failure

Introduction: Noninvasive positive pressure ventilation (NIPPV) has become an integral tool in the management of acute hypercapnic respiratory failure (AHRF) in chronic obstructive pulmonary disease (COPD). This study was performed to evaluate the early effects of NIPPV on pulmonary artery pressure (PAP), serum N-terminal pro BNP (NT-proBNP), and ventilatory parameters in the COPD patients with...

متن کامل

Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there was no spacer between the membrane and glass of the electrode. Use of this filli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 61 1  شماره 

صفحات  -

تاریخ انتشار 2016