BACKGROUND The purpose of this study was to compare DNA histograms obtained by standard flow cytometry (FC) and high fidelity image cytometry on sections (ICS) in normal gastrointestinal mucosa and Barrett's adenocarcinoma (BAC). METHODS Archival formalin-fixed paraffin-embedded tissue blocks of 10 normal controls from 10 subjects and 42 BAC tissues from 17 patients were examined. DNA FC was performed using standard techniques and ICS was carried out by Automated Cellular Imaging System (ACIS). DNA ploidy histograms were classified into diploid with peak DNA index (DI) at 0.9-1.1, and aneuploid with peak DI > 1.1. DI values of aneuploid peaks were determined. Additionally, for DNA ICS, heterogeneity index (HI) representing DNA content heterogeneity, and histograms containing cells with DI > G2 were also identified. RESULTS All control samples were diploid by both FC and ICS analyses. In BAC, FC showed diploid peaks in 29%, diploid peaks with additional aneuploid or tetraploid peaks in 57%, and 14% of the samples, respectively. In contrast, ICS showed aneuploid peaks in all the cases with peak DI > 1.25; 37 cases had peak DI between 1.25 and 2.25; and 5 cases had peak DI > 2.25. HI values (mean +/- SD) were 11.3 +/- 1.1 in controls and 32.4 +/- 8.5 in BAC (p < 0.05). Controls had no G2 exceeding cells. However, 19/37 (51%) of the cases with primary peak DI < 2.25 had cells exceeding 9N. CONCLUSION ICS detects DNA aneuploidy in all BAC samples while FC missed the diagnosis of aneuploidy in 29%. In addition, ICS provides more information on HI and G2 exceeding rates.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of image analysis and flow cytometric determination of cellular DNA content.

A good correlation (r = 0.94) was obtained between the DNA indices (DI) using flow cytometry and image analysis of nuclei cytospins extracted from paraffin wax embedded tumour sections. Some of the limitations and problems associated with image analysis which came to light included an unacceptably high coefficient of variation (CV) and a "left-shift" in the DI in most DNA histograms obtained wh...

متن کامل

DNA index determination with Automated Cellular Imaging System (ACIS) in Barrett's esophagus: Comparison with CAS 200

BACKGROUND For solid tumors, image cytometry has been shown to be more sensitive for diagnosing DNA content abnormalities (aneuploidy) than flow cytometry. Image cytometry has often been performed using the semi-automated CAS 200 system. Recently, an Automated Cellular Imaging System (ACIS) was introduced to determine DNA content (DNA index), but it has not been validated. METHODS Using the C...

متن کامل

Value of DNA image cytometry in the prediction of malignant change in Barrett's oesophagus.

DNA image cytometry was performed on Feulgen stained sections from 91 biopsies obtained during prospective endoscopic surveillance of 55 patients with Barrett's oesophagus. Aneuploid cells were detected in specimens from six of these patients. Four subsequently developed dysplasia and adenocarcinoma but, in the other two, biopsies had been reported as showing specialised epithelium only, with n...

متن کامل

Quadratic form: a robust metric for quantitative comparison of flow cytometric histograms.

Comparison of fluorescence distributions is a fundamental part of the analysis of flow cytometric data. This approach is applied to detect differences between control and test sample and thus analyze a biological response. Comparison of standard test samples over time provides an estimate of instrument stability for quality control. However, application of statistical methods of distribution co...

متن کامل

DNA Index Determination with Automated Cellular Imaging System (ACIS) in Barrett's Esophagus: Comparison with CAS

Background: For solid tumors, image cytometry has been shown to be more sensitive for diagnosing DNA content abnormalities (aneuploidy) than flow cytometry. Image cytometry has often been performed using the semi-automated CAS 200 system. Recently, an Automated Cellular Imaging System (ACIS) was introduced to determine DNA content (DNA index), but it has not been validated. Methods: Using the C...

متن کامل