Dose Calibrator Performance and Quality Control

نویسنده

  • Francis H. Chan
چکیده

Two different dose calibrators were studied and their performance measured using the following tests: (A) linearity of response over all activity ranges, (B) accuracy when measuring some commonly used radionuclides, (C) the effect of container configuration on the accuracy of measurement, and (D) daily and long-term stability of the instrument. For each instrument tested, a good linear response was observed for activity measurements below 100 mCi, but there was evidence of nonlinearity at higher activity levels. The accuracy of each instrument was checked using radionuclide standards from two different sources. The measurements indicated a significant difference between standards that was not possible to resolve. Additionally, assessment of accuracy for a dose calibrator with any standard is difficult unless the manufacturer's calibration procedure is known. The effect of container configuration and photon energy on the accuracy of measuring 99 .. Tc, 13IJ, and I25J indicated that large correction factors may be necessary when making measurements of 125/. The measurement of a long-lived standard such as radium, cross calibrated for several radionuclide settings, is an effective means for assurring instrument stability and quality control on a daily and longterm basis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Control Testing of Dose Calibrators

We have reviewed quality control testing of dose calibrators and have analyzed the potential for error. The uncertainty in half-lives of reference sources can lead to inaccurate assessment of the accuracy and constancy in dose calibrator performance. Molybdenum-99 contamination of '"Tc used as a reference source can appear as a nonlinear response of the dose calibrator. The useful life of a ref...

متن کامل

Multicentre harmonization of 89Zr PET/CT performance

This study investigated the feasibility of quantitative accuracy and harmonized image quality in Zr-PET/CT multicentre studies. Methods: Five PET/CT scanners from 3 vendors were included. Zr activity was measured in a central dose calibrator before delivery.Local activity assays were based on volume as well as on the local dose calibrator. Accuracy and image noise were determined from a cross c...

متن کامل

Multicenter harmonization of 89Zr PET/CT performance.

UNLABELLED This study investigated the feasibility of quantitative accuracy and harmonized image quality in (89)Zr-PET/CT multicenter studies. METHODS Five PET/CT scanners from 3 vendors were included. (89)Zr activity was measured in a central dose calibrator before delivery. Local activity assays were based on volume as well as on the local dose calibrator. Accuracy and image noise were dete...

متن کامل

Routine quality control of clinical nuclear medicine instrumentation: a brief review.

This article reviews routine quality-control (QC) procedures for current nuclear medicine instrumentation, including the survey meter, dose calibrator, well counter, intraoperative probe, organ ("thyroid") uptake probe, gamma-camera, SPECT and SPECT/CT scanner, and PET and PET/CT scanner. It should be particularly useful for residents, fellows, and other trainees in nuclear medicine, nuclear ca...

متن کامل

Characterization of geometric uncertainties of a dose calibrator during measurement of 90Y activity.

UNLABELLED The performance and measurement of (90)Y with a dose calibrator has always been a key point of several international recommendations, specifically in the case of the radiopharmaceutical (90)Y-ibritumomab tiuxetan, among other applications, used in the treatment of non-Hodgkin lymphoma. The objective of the present work was to examine in detail some important sources of geometric erro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014