A compact, high performance atomic magnetometer for biomedical applications.

نویسندگان

  • Vishal K Shah
  • Ronald T Wakai
چکیده

We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) magnetometers. We present side-by-side comparisons between our AM and a SQUID magnetometer, and show that equally high quality magnetoencephalography and magnetocardiography recordings can be obtained using our AM.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum: Vectorized magnetometer for space applications using electrical readout of atomic scale defects in silicon carbide

Magnetometers are essential for scientific investigation of planetary bodies and are therefore ubiquitous on missions in space. Fluxgate and optically pumped atomic gas based magnetometers are typically flown because of their proven performance, reliability, and ability to adhere to the strict requirements associated with space missions. However, their complexity, size, and cost prevent their a...

متن کامل

Cross-validation of microfabricated atomic magnetometers with superconducting quantum interference devices for biomagnetic applications

We compare the performance of a chip-scale atomic magnetometer CSAM with that of a superconducting quantum interference device SQUID sensor in two biomedical applications. Magnetocardiograms MCGs of healthy human subjects were measured simultaneously by a CSAM and a multichannel SQUID sensor in a magnetically shielded room. The typical features of MCGs are resolved by the CSAM, matching the SQU...

متن کامل

A High-Sensitivity Tunable Two-Beam Fiber-Coupled High-Density Magnetometer with Laser Heating

Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz1/2 sensitivity at low frequency (50 Hz), whi...

متن کامل

Chip - Scale Room - Temperature Atomic Magnetometers for Biomedical Measurements

We describe a portable four-channel array of chip-scale atomic magnetometers in a flexible flying-lead configuration. These microfabricated, uncooled sensors with volumes below 1 cm 3 demonstrate sensitivities around 100 fT/Hz 1/2 and bandwidths of several hundred hertz. Performance limits are discussed, as the design is easily scalable to different sensor sizes and large arrays. Initial measur...

متن کامل

Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array.

We present a portable four-channel atomic magnetometer array operating in the spin-exchange relaxation-free regime. The magnetometer array has several design features intended to maximize its suitability for biomagnetic measurement, specifically foetal magnetocardiography, such as a compact modular design and fibre-coupled lasers. The modular design allows the independent positioning and orient...

متن کامل