Validated spectrofluorimetric method for the determination of atorvastatin in pharmaceutical preparations

نویسندگان

  • Mohie M.K. Sharaf El-Din
  • Fathy M.M. Salama
  • Mohamed W.I. Nassar
  • Khalid A.M. Attia
  • Mohamed M.Y. Kaddah
چکیده

A rapid, sensitive and simple spectrofluorimetric method was developed for the estimation of atorvastatin. In this method, the native fluorescence characteristics of atorvastatin have been studied in both acidic and basic media. High sensitivity was obtained with 5% acetic acid at 389 nm using 276 nm for excitation. Regression analysis showed a good correlation coefficient (r=0.9995) between fluorescence intensity and concentration over the range of 1.5-4 μg/mL with detection limit of 0.012 μg/mL. The proposed method was successfully applied to the analysis of atorvastatin in pure and pharmaceutical dosage forms with average recovery of 100.29±0.47%. The results were compared favorably with those of the reported method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Validated stability-indicating spectrofluorimetric methods for the determination of ebastine in pharmaceutical preparations

Two sensitive, selective, economic, and validated spectrofluorimetric methods were developed for the determination of ebastine (EBS) in pharmaceutical preparations depending on reaction with its tertiary amino group. Method I involves condensation of the drug with mixed anhydrides (citric and acetic anhydrides) producing a product with intense fluorescence, which was measured at 496 nm after ex...

متن کامل

Simultaneous Determination Of Ezetimibe And Atorvastatin Calcium In Binary Mixture By Second Derivative (D) Spectrofluorimetric Method

Analytical Chemistry Department, Faculty of Pharmacy, Modern University for Technology and Information, Cairo, Egypt Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt Biotechnology Centre, Faculty of Pharmacy, Cairo University, Cairo, Egypt Pharmaceutical Chemistry Department, Faculty of Pharmaceutical Sciences and Pharmaceutical Industries, Future University,...

متن کامل

Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012