Effects of Non-Elevation-Focalized Linear Array Transducer on Ultrasound Plane-Wave Imaging

نویسندگان

  • Congzhi Wang
  • Yang Xiao
  • Jingjing Xia
  • Weibao Qiu
  • Hairong Zheng
چکیده

Plane-wave ultrasound imaging (PWUS) has become an important method of ultrasound imaging in recent years as its frame rate has exceeded 10,000 frames per second, allowing ultrasound to be used for two-dimensional shear wave detection and functional brain imaging. However, compared to the traditional focusing and scanning method, PWUS images always suffer from a degradation of lateral resolution and contrast. To improve the image quality of PWUS, many different beamforming algorithms have been proposed and verified. Yet the influence of transducer structure is rarely studied. For this paper, the influence of using an acoustic lens for PWUS was evaluated. Two linear array transducers were fabricated. One was not self-focalized in the elevation direction (non-elevation-focalized transducer, NEFT); the other one was a traditional elevation-focalized transducer (EFT). An initial simulation was conducted to show the influence of elevation focusing. Then the images obtained with NEFT on a standard ultrasound imaging phantom were compared with those obtained with EFT. It was demonstrated that, in a relatively deep region, the contrast of an NEFT image is better than that of an EFT image. These results indicate that a more sophisticated design of ultrasound transducer would further improve the image quality of PWUS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Simulation of B-scan images from two-dimensional transducer arrays: Part II--Comparisons between linear and two-dimensional phased arrays.

Two-dimensional (2-D) arrays have been proposed as a solution to the degradation in medical ultrasound image quality occurring as a result of asymmetric focusing properties of linear phased array transducers. The 2-D phased transducer array is also capable of electronically steering the symmetrically focused ultrasound beam throughout a three-dimensional volume. In a companion paper the potenti...

متن کامل

Quantitative, Free-Hand 3D Ultrasound Imaging based on a Modified 1D Transducer Array

An approach for acquiring dimensionally accurate 3D ultrasound data, based on a modified 1D transducer array, is presented. The method avoids many of the drawbacks of conventional approaches to 3D ultrasound data acquisition. Scanning is simple and easy to perform in a clinical setting. A modified 1D transducer array is employed comprising a central conventional 1D ‘Imaging’ array and two perpe...

متن کامل

Focused ultrasound in ophthalmology

The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, m...

متن کامل

High frame rate ultrasonic imaging through Fourier transform using an arbitrary known transmission field

Based on the study of limited array diffraction beams, a High Frame Rate (HFR) imaging method which uses a broadband pulsed plane wave, or array beams transmission field from a linear transducer array to illuminate the area to be imaged has been developed by Jian-yu LU. Echoes from the objects are received with the same transducer as is used in transmission. For each array beam parameter in a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016