Intraspinal metalloma causing lumbar stenosis after interbody fusion with cylindrical titanium cages.
نویسندگان
چکیده
Intraspinal metallomas are rare. The authors present a case after implantation of two titanium threaded interbody cages at the L4L5 level, without posterior instrumentation. To their knowledge this is the first case due to intervertebral cages. The lack of additional instrumentation had probably allowed the cages to make contact. Subsequently, friction generated wear debris, which led to the formation of a granuloma, responsible for compression of the dural sac. Intraspinal metallosis should be kept in mind as an infrequent cause of delayed neurological symptoms after spinal surgery with metallic instrumentation.
منابع مشابه
Report on two failed posterior lumbar interbody fusions
Despite X-ray and computed tomography signs of osseous stability after posterior lumbar interbody fusion (PLIF) procedures, the examination of two patients after 28 and 24 months respectively, revealed that the cages were wandering and consolidation had not taken place. Revision surgery was required in both cases. Introduction Fusion surgery in the region of the lumbar spine has become standard...
متن کاملPosterior lumbar interbody fusion (PLIF) with cages and local bone graft in the treatment of spinal stenosis.
Posterior lumbar interbody fusion (PLIF) implants are increasingly being used for 360 degrees fusion after decompression of lumbar spinal stenosis combined with degenerative instability. Both titanium and PEEK (PolyEtherEtherKetone) implants are commonly used. Assessing the clinical and radiological results as well as typical complications, such as migration of the cages, is important. In addit...
متن کاملExtraforaminal Lumbar Interbody Fusion for Cage Migration after Screw Removal: A Case Report
The use of titanium cages for posterior lumbar interbody fusion (PLIF) has gained popularity because it offers the advantages of anterior column support and stabilization. However, cage migration into the spinal canal may have severe or disastrous consequences. Here, the authors report an unexpected case of posterior migration of fusion cages after screw removal in a patient that underwent PLIF...
متن کاملMorphological analysis of interbody fusion following posterior lumbar interbody fusion with cages using computed tomography
Posterior lumbar interbody fusion (PLIF) using cages in conjunction with pedicle screw fixation is considered the gold standard for surgical treatment of degenerative lumbar spine disorders due to its biomechanical stability and high fusion rate. However, research regarding patterns of fusion in the interbody space during the early postoperative period is lacking.Sixty consecutive patients were...
متن کاملCT evaluation of lumbar interbody fusion: current concepts.
Operative techniques for fusing an unstable portion of the lumbar spine or immobilizing a painful vertebral motion segment have been in use for many years. Lumbar fusion procedures initially were used to treat patients with infections (tuberculous spondylitis) or misaligned spines (isthmic spondylolisthesis) (1–8). Early techniques involving the use of harvested autogenous bone graft without in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 78 6 شماره
صفحات -
تاریخ انتشار 2012