Protein Preconcentration Using Nanofractures Generated by Nanoparticle-Assisted Electric Breakdown at Junction Gaps

نویسندگان

  • Chun-Ping Jen
  • Tamara G. Amstislavskaya
  • Chen-Chi Kuo
  • Yu-Hung Chen
چکیده

Sample preconcentration is an important step that increases the accuracy of subsequent detection, especially for samples with extremely low concentrations. Due to the overlapping of electrical double layers in the nanofluidic channel, the concentration polarization effect can be generated by applying an electric field. Therefore, a nonlinear electrokinetic flow is induced, which results in the fast accumulation of proteins in front of the induced ionic depletion zone, the so-called exclusion-enrichment effect. Nanofractures were created in this work to preconcentrate proteins via the exclusion-enrichment effect. The protein sample was driven by electroosmotic flow and accumulated at a specific location. The preconcentration chip for proteins was fabricated using simple standard soft lithography with a polydimethylsiloxane replica. Nanofractures were formed by utilizing nanoparticle-assisted electric breakdown. The proposed method for nanofracture formation that utilizes nanoparticle deposition at the junction gap between microchannels greatly decreases the required electric breakdown voltage. The experimental results indicate that a protein sample with an extremely low concentration of 1 nM was concentrated to 1.5×10(4)-fold in 60 min using the proposed chip.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sample Preconcentration Utilizing Nanofractures Generated by Junction Gap Breakdown Assisted by Self-Assembled Monolayer of Gold Nanoparticles

The preconcentration of proteins with low concentrations can be used to increase the sensitivity and accuracy of detection. A nonlinear electrokinetic flow is induced in a nanofluidic channel due to the overlap of electrical double layers, resulting in the fast accumulation of proteins, referred to as the exclusion-enrichment effect. The proposed chip for protein preconcentration was fabricated...

متن کامل

An Integrated Micro-nanofluidic System for Sample Preparation and Preconcentration of Proteins

In this study, an integrated micro-nanofluidic system for protein analysis was presented. The device is comprised of a micromixer and a preconcentrator with a separation column. The Integrated micromixer based on unbalanced split and cross collision of fluid streams is passive and planar, which is easy to fabricate and integrate to the microfluidic system. The preconcentrator has nanochannels f...

متن کامل

Flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry for the preconcentration and determination of cadmium (II) after optimization using experimental design

Arapid, highly sensitive and efficient flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry has been proposed for the preconcentration and quantitative analysis of trace amounts of cadmium (II) in the presence of sodium diethyldithiocarbamateas complexingagent. Parameters including sample pH, concentration of the complexingagent, ...

متن کامل

Preconcentration and Separation of Mixed-Species Samples Near a Nano-Junction in a Convergent Microchannel

A fluidic microchip incorporating a convergent microchannel and a Nafion-nanoporous membrane is proposed for the preconcentration and separation of multi-species samples on a single platform. In the device, sample preconcentration is achieved by means of the ion concentration polarization effect induced at the micro/nano interface under the application of an external electric field, while speci...

متن کامل

4H-SiC Diode Avalanche Breakdown Voltage Estimation by Simulation and Junction Termination Extension Analysis

This paper presents and compares different avalanche breakdown voltage estimation methods in 4H-SiC (silicon carbide) using finite element simulation results on Schottky diode. 4H-SiC avalanche breakdown voltage and depletion width estimated with Baliga’s equations have shown to be higher than other estimation techniques and simulation results, especially for voltages higher than 5kV. This pape...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014