Construction and evaluation of a miniature electron ion coincidence analyzer mounted on a conflat flange with an outer diameter of 114 mm.

نویسندگان

  • Takuhiro Kakiuchi
  • Eiichi Kobayashi
  • Koji K Okudaira
  • Narihiko Fujita
  • Masatoshi Tanaka
  • Kazuhiko Mase
چکیده

We have developed a miniature electron ion coincidence (EICO) analyzer mounted on a conflat flange with an outer diameter of 114 mm. It consists of a cylindrical mirror analyzer (CMA), a time-of-flight ion mass spectrometer (TOF-MS), a commercially available linear motion feed through, and a tilt adjustment mechanism. Each sample surface was irradiated by synchrotron radiation, and the energies of emitted electrons were analyzed and detected by the CMA, while desorbed ions were collected by the TOF-MS in coincidence with the electrons. The performance of the EICO analyzer was tested by measuring the Auger-electron H+ photoion coincidence spectrum of condensed water at 4a1 <-- O 1s resonance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Miniature mass spectrometer systems based on a microengineered quadrupole filter.

Two miniature mass spectrometer systems based on a microengineered quadrupole mass filter have been developed. One of the instruments has a footprint of 27 cm x 20 cm and is intended for laboratory use when space is at a premium. The other is portable and intended for use in the field. It is battery powered, weighs 14.9 kg, and is housed in a rugged case. This is the first example of a portable...

متن کامل

Technical note: development of a duodenal cannula for sheep.

A single T-shaped duodenal cannula of silicone rubber with a gutter-type small inner flange was developed for sheep. The barrel of the cannula was 24 mm long with an internal diameter of 12 mm. A polyester surgical mesh (100 mm x 100 mm) was connected to the barrel of the cannula as an anchor. Fibrous tissues grew on the polyester mesh anchor and adhered firmly to the serosa of the intestine, t...

متن کامل

Comparison of Diagnostic Value of Cast Analyzer X Iranian Software versus Curve Expert Software for Arch Form Construction based on Mathematical Models

  Objective: For the assessment of primary arch form, different methods have been used including qualitative classifications, inter-canine and inter-molar widths and quantitative and numerical methods using mathematical models. The purpose of this study was to compare the validity and reliability of Cast Analyzer X Iranian software with those of Curve Expert Professional version 1.1 for arch fo...

متن کامل

Laboratory evaluation of shear bond strength of porcelain repair methods

Introduction: Porcelain fracture is a relatively common problem in clinical dental practice. Various methods have been proposed for repairing porcelain fractures including direct composite resin repair or construction of a porcelain laminate veneer and its cementation with a resin cement. Evaluation of shear bond strength of porcelain repair methods was the purpose of this study. Methods: Tw...

متن کامل

Design and Construction of an Aerosol Particle Classification System Based on Electrical Mobility

Introduction: The application of particles’ electrical mobility in the electric field has always been an important concern, as the functional basis of a number of particle measuring and classification instrumentations. The objective of this study was to design and construct an aerosol particles classification system using electrical mobility feature in laboratory scale. Methodology: This labo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2008