Computerized endoscopic surgical grasper.
نویسندگان
چکیده
We report a computerized endoscopic surgical grasper with computer control and a force feedback (haptic) user interface. The system uses standard unmodified grasper shafts and tips. The device can control grasping forces either by direct surgeon control, via teleoperation, or under software control. In this paper, we test an automated palpation function in which the grasper measures mechanical properties of the grasped tissue by applying a programmed series of squeezes. Experimental results show the ability to discriminate between the normal tissues of small bowel, lung, spleen, liver, colon, and stomach. We anticipate applications in telesurgery, clinical endoscopic surgery, surgical training, and research.
منابع مشابه
An Endoscopic Grasper Tool with a Supported Piezoelectric Tactile Sensor
In this study, we describe the design of a tactile sensor based on polyvinylidene fluoride (PVDF). The sensor exhibits high force sensitivity and linearity. This sensor is integrated with an endoscopic grasper tool and can be used in minimally invasive surgeries. It consists of three distinct layers. A rigid micro-machined tooth-like silicon constitutes the top layer of the grasper, and the Ple...
متن کاملComputer-controlled motorized endoscopic grasper for in vivo measurement of soft tissue biomechanical characteristics.
Accurate biomechanical characteristics of tissues are essential for developing realistic virtual reality surgical simulators utilizing haptic devices. Surgical simulation technology has progressed rapidly but without a large database of soft tissue mechanical properties with which to incorporate. The device described here is a computer-controlled, motorized endoscopic grasper capable of applyin...
متن کاملTransvaginal Appendectomy in Morbidly Obese Patient
Introduction. Laparoscopic appendectomy has significant benefits in obese patients. However, morbid obesity can be accepted as an exclusion criterion for natural orifice transluminal endoscopic surgery (NOTES). Here, we present a transvaginal appendectomy in a 66-year-old morbidly obese (BMI 36 kg/m(2), ASA III) patient. Case and Technique. Acute appendicitis was suspected based on history, phy...
متن کاملOptimization of a piezoelectric bimorph grasper for use in minimally invasive surgical applications
The potential use of piezoelectric bimorph actuators in minimally invasive surgery suture-needle grasper/holder applications is explored computationally. Upon defining the design/functional requirements for such surgical tools, a finite element analysis of the underlying piezoelectric boundary value problem is combined with the genetic algorithm optimization routine to arrive at an optimal morp...
متن کاملThe impact on clinical practice of endoscopic ultrasonography used for the diagnosis and staging of pancreatic adenocarcinoma.
CONTEXT Endoscopic ultrasonography is considered a highly accurate procedure for diagnosing small pancreatic tumors and assessing their locoregional extension. OBJECTIVE To evaluate the impact of endoscopic ultrasonography on the management of pancreatic adenocarcinoma in clinical practice. PATIENTS Sixty-four consecutive patients (mean age 70.5 plus/minus 11.9 years) hospitalized for stagi...