Low energy defibrillation in human cardiac tissue: a simulation study.

نویسندگان

  • Stuart W Morgan
  • Gernot Plank
  • Irina V Biktasheva
  • Vadim N Biktashev
چکیده

We aim to assess the effectiveness of feedback-controlled resonant drift pacing as a method for low energy defibrillation. Antitachycardia pacing is the only low energy defibrillation approach to have gained clinical significance, but it is still suboptimal. Low energy defibrillation would avoid adverse side effects associated with high voltage shocks and allow the application of implantable cardioverter defibrillator (ICD) therapy, in cases where such therapy is not tolerated today. We present results of computer simulations of a bidomain model of cardiac tissue with human atrial ionic kinetics. Reentry was initiated and low energy shocks were applied with the same period as the reentry, using feedback to maintain resonance. We demonstrate that such stimulation can move the core of reentrant patterns, in the direction that depends on the location of the electrodes and the time delay in the feedback. Termination of reentry is achieved with shock strength one-order-of-magnitude weaker than in conventional single-shock defibrillation. We conclude that resonant drift pacing can terminate reentry at a fraction of the shock strength currently used for defibrillation and can potentially work where antitachycardia pacing fails, due to the feedback mechanisms. Success depends on a number of details that these numerical simulations have uncovered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanisms of Defibrillation Failure

Since defibrillation by high-energy electric shocks is the only effective means for termination of ventricular fibrillation, defibrillation shocks are now widely used in clinical practice for prevention of sudden cardiac death. However, the high-energy shocks could result in myocardial dysfunction and damage (Runsio et al., 1997) and in psychological trauma (Maisel, 2006). Comprehensive underst...

متن کامل

Evaluation of the dose and flux of secondary particles in the lung tissue in breast proton therapy using the Monte Carlo simulation code

Unlike proton therapy, conventional radiation therapy directs X-rays not only at the tumor but also unavoidably at nearby healthy tissue. Protons deliver radiation to tumor tissue while the healthy structures will be spared during proton therapy. When protons travel through matter, secondary particles like neutrons and photons are produced. It is believed that the secondary dose can lead to sec...

متن کامل

Extension of Refractoriness in a Model of Cardiac Defibrillation

This simulation study presents an inquiry into the mechanisms by which a strong electric shock halts life-threatening cardiac arrhythmias. It examines the "extension of refractoriness" hypothesis for defibrillation which postulates that the shock induces an extension of the refractory period of cardiac cells thus blocking propagating waves of arrhythmia and fibrillation. The present study uses ...

متن کامل

Low-energy cardioversion with epicardial wire electrodes: new treatment of atrial fibrillation after open heart surgery.

BACKGROUND Atrial fibrillation (AF) is the most common arrhythmia after open heart surgery. Traditional treatment with a range of antiarrhythmic drugs and electrical cardioversion is associated with considerable side effects. The aim of this study was to examine the feasibility and efficacy of low-energy atrial defibrillation with temporary epicardial defibrillation wire electrodes. METHODS A...

متن کامل

Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS).

BACKGROUND Traditionally, a safety margin of at least 10 J between the maximum output of the pulse generator and the energy needed for ventricular defibrillation has been used because lower safety margins were associated with unacceptably high rates of failed defibrillation and sudden cardiac death. The Low Energy Safety Study (LESS) was a prospective, randomized assessment of the safety margin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biophysical journal

دوره 96 4  شماره 

صفحات  -

تاریخ انتشار 2009