[Rebound tonometry in a clinical setting. Comparison with applanation tonometry].

نویسندگان

  • C López-Caballero
  • I Contreras
  • F J Muñoz-Negrete
  • G Rebolleda
  • L Cabrejas
  • P Marcelo
چکیده

PURPOSE Rebound tonometry has recently been modified for its use in humans. The purpose of our study was to determine the precision of the ICare(R) rebound tonometer (RBT) as compared with the Goldmann applanation tonometer (GAT). METHODS Patients were recruited from our Hospital's Glaucoma Unit. In each patient, intraocular pressure (IOP) was measured without anaesthesia using the RBT and ten minutes later using the GAT. Central corneal thickness (CCT) was measured by pachymetry. RESULTS Sixty-eight patients were recruited (132 eyes). Mean IOP readings with RBT were 18.9 +/- 7.2 (SD) mmHg and were 15.5 +/- 5.7 mmHg with GAT (p<0.001). There was a good correlation between both instruments (r = 0.87, p<0.001). In most cases (84.6%) the IOP measured with the RBT was greater than that measured with the GAT. The mean difference between both instruments was 3.4 +/- 3.6 mmHg. There was a trend towards greater differences between those obtained using the RBT than the GAT when IOP values were higher. A statistically significant correlation was found between IOP readings with both tonometers and CCT, with higher differences being seen as the CCT increased. CONCLUSION The RBT can be employed in a clinical setting taking into account that it usually overestimates IOP as compared with the GAT. It could be especially useful in glaucoma screening campaigns since it can be operated by a trained technician.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Comparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: a cohort study

OBJECTIVE To test agreement of two methods to measure intraocular pressure (IOP): rebound tonometry (RBT) and gold standard Goldmann applanation tonometry (GAT) in children with glaucoma. DESIGN Observational prospective cohort study. SETTING Tertiary paediatric glaucoma clinic at a single centre. PARTICIPANTS 102 individuals attending a paediatric glaucoma clinic, mean (SD) age 11.85 (3....

متن کامل

Comparison of Rebound Tonometry, Perkins Applanation Tonometry and Ocular Response Analyser in Mucopolysaccharidosis Patients

AIMS To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA). METHODS MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in...

متن کامل

A Comparison of the Icare Pro Rebound Tonometer with Applanation Tonometry in Healthy Infants

The measurement of intraocular pressure (IOP) in children is an important component of the ocular examination, but can be challenging, especially in younger children and infants. Clinical suspicion of raised IOP necessitates examination under anaesthesia. This is costly [1], associated with potentially serious adverse events [2], including developmental delay [3], and uses valuable paediatric t...

متن کامل

Evaluation of a new rebound tonometer for self-measurement of intraocular pressure Sub-title Self-measurement using Icare Home showed good agreement with Goldmann applanation

Title Evaluation of a new rebound tonometer for self-measurement of intraocular pressure Subtitle Self-measurement using Icare Home showed good agreement with Goldmann applanation tonometry. Icare Home self-measurement was well accepted and reliable results obtained by 3 in 4 subjects, suggesting potential use for home measurement of intraocular pressure. Number of references = 26 Number of sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de la Sociedad Espanola de Oftalmologia

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 2007