Application of Ann Methods for Instrument Transformer Correction in Transmission Line Protection

نویسندگان

  • M M Saha
  • J Izykowski
  • M Lukowicz
  • E Rosolowski
چکیده

Current and voltage transformers influence the criterion values measurement particularly during disturbances in the system. Certain construction limitations of instrument transformers may in some cases cause maloperation or substantial delay in tripping of the protective relays. Current transformer saturation and discharging of the capacitive voltage transformer’s internal energy during short circuits on an associated transmission line are the most important phenomena affecting accuracy of the voltage and current magnitude estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavelet and ANN Based Relaying for Power Transformer Protection

This paper presents an efficient wavelet and neural network (WNN) based algorithm for distinguishing magnetizing inrush currents from internal fault currents in three phase power transformers. The wavelet transform is applied first to decompose the current signals of the power transformer into a series of detailed wavelet components. The values of the detailed coefficients obtained can accurate...

متن کامل

Artificial Intelligence Based Approach for Identification of Current Transformer Saturation from Faults in Power Transformers

Protection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, proper and quick identification of Current transformer saturation is so important. In this paper, an Artificial Neural Network...

متن کامل

A Novel Method to Increase the Power Capacity of Transmission Lines Using Transformerless Static Synchronous Series Compensator

In this paper a transformerless Static Synchronous Series Compensator (SSSC) to increase the power capacity of a 230 kV transmission line is proposed. In order to eliminate the transformer, a 15-level cascade H Bridge (CHB) inverter is employed within the proposed compensator structure to inject reactive power to the transmission line. The theory of instantaneous p-q power using in the compensa...

متن کامل

A Sensitive ANN Based Differential Relay for Transformer Protection with Security against CT Saturation and Tap Changer Operation

This paper presents an artificial neural network (ANN) based scheme for fault identification in power transformer protection. The proposed scheme is featured by the application of ANN to identifying system patterns, the unique choice of harmonics of positive sequence differential currents as ANN inputs, the effective handling of current transformer (CT) saturation with an ANN based approach, an...

متن کامل

Artificial Intelligent Application to Power System Protection

The application of Artificial Intelligence (AI) methods in power system protection has been addressed in this paper. Particular emphasis has been put on Artificial Neural Networks (ANN) and Fuzzy Logic (FL). Several novel concepts have been introduced including ANN application to CT and CVT transients correction, fuzzy criteria signals, fuzzy settings and multi-criteria decision making for digi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000