Geometric orientation of the aortic neoroot in patients with raphed bicuspid aortic valve disease undergoing primary cusp repair and a root reimplantation procedure.
نویسندگان
چکیده
OBJECTIVES Primary cusp repair + aortic root reimplantation in bicuspid aortic valve (BAV) disease presenting with root aneurysm with aortic insufficiency (AI) is an effective surgical treatment. We assessed whether the geometric orientation of the repaired BAV into its reimplanted neoroot affects outcomes-180°/180° orientation was compared with the 150°/210° orientation. METHODS From 2005 to 2012, 66 BAV repairs were performed. This is a retrospective review of all types of Ib/II BAV AI patients undergoing root reimplantation (n = 26) at two different geometric orientations: 180°/180° (n = 11) vs 150°/210° (n = 15). In the 180°/180° group, reimplantation into the neoroot was such that both conjoint and non-conjoint cusps occupied 180° of the annular circumference. In the 150°/210° group, the repaired valve was configured to the more typical native orientation of a type I BAV: the non-conjoint cusp occupied 150°, and the conjoint cusp occupied 210° of the annular circumference. RESULTS Preoperative characteristics were similar in both groups. In-hospital mortality, stroke, reoperation, renal failure and pacemaker rates were zero in both groups. No patient left the operating room with >1+ AI and one had a peak gradient >20 mmHg. Transvalvular gradients were higher in the 180°/180° group, but not significant (P > 0.05). M.ean follow-ups for the 180°/180° and 150°/210° group were 48 and 33 months, respectively. Actuarial freedom from AI >2+ at 5 years was 100% in both groups. Freedom from AI >1+ at 5 years was 90 ± 10% in the 150°/210° group and 86 ± 13% in the 180°/180° group (P = 0.71). Freedom from peak gradient >20 mmHg was 80% (n = 8) in the 180°/180° group and 100% in the 150°/210° group at 1-year follow-up. Transvalvular gradients were higher in the 180°/180° group (16 ± 8 vs 10 ± 4 mmHg, P = 0.02; 9 ± 3 vs 5 ± 3 mmHg, P = 0.01). Five-year actuarial survival and freedom from aortic reoperation have remained at 100% in the entire cohort. CONCLUSION Cusp repair + root reimplantation for BAV type Ib/II AI can be safely performed at either geometric orientation. Conceptually, 150°/210° orientation respects the natural type I BAV anatomy with regard to cusp surface area and leaflet insertion perimeter. The 180°/180° group may have higher transvalvular gradients and smaller coaptation zones than the 150°/210° group. Further follow-up may reveal the superiority of one geometric orientation over the other.
منابع مشابه
Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملNew vascular graft for simplification of the aortic valve reimplantation technique.
Achievement of optimal valve geometry in valve-sparing aortic root repairs is a prerequisite for favorable valve function and, therefore, the simplification of these procedures is of utmost importance. The aim of the study was to determine the feasibility of the new vascular graft for aortic valve reimplantation technique and evaluate the early and intermediate functional results. Five patients...
متن کاملEffect of annulus dimension and annuloplasty on bicuspid aortic valve repair.
OBJECTIVES We have recently shown that valve sparing reimplantation (VSR) improves the durability of bicuspid aortic valve repair in comparison with subcommissural annuloplasty. The aim of this study was to assess the degree of annular reduction provided by these techniques and to correlate these findings with repair durability. METHODS From 1995 to 2010, 161 patients underwent bicuspid valve...
متن کاملValve configuration determines long-term results after repair of the bicuspid aortic valve.
BACKGROUND Reconstruction of the regurgitant bicuspid aortic valve has been performed for >10 years, but there is limited information on long-term results. We analyzed our results to determine the predictors of suboptimal outcome. METHODS AND RESULTS Between November 1995 and December 2008, 316 patients (age, 49±14 years; male, 268) underwent reconstruction of a regurgitant bicuspid aortic va...
متن کاملCusp height in aortic valves.
OBJECTIVES Successful aortic valve repair must normalize cusp and root dimensions. Limited information is available on the normal dimensions of human cusps, in particular the cusp height. METHODS The cusp height was measured intraoperatively in 621 patients during aortic valve repair procedures. A tricuspid anatomy was present in 329 patients and bicuspid in 286 patients. In addition, patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 45 1 شماره
صفحات -
تاریخ انتشار 2014