Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

نویسندگان

  • Adrian R Kendal
  • Daniel Prieto-Alhambra
  • Nigel K Arden
  • Andrew Carr
  • Andrew Judge
چکیده

OBJECTIVES To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. DESIGN Retrospective cohort study. SETTING English hospital episode statistics database linked to mortality records from the Office for National Statistics. POPULATION All adults who underwent primary elective hip replacement for osteoarthritis from April 1999 to March 2012. The exposure of interest was prosthesis type: cemented total hip replacement, uncemented total hip replacement, and metal-on-metal hip resurfacing. Confounding variables included age, sex, Charlson comorbidity index, rurality, area deprivation, surgical volume, and year of operation. MAIN OUTCOME MEASURES All cause mortality. Propensity score matching was used to minimise confounding by indication. Kaplan-Meier plots estimated the probability of survival up to 10 years after surgery. Multilevel Cox regression modelling, stratified on matched sets, described the association between prosthesis type and time to death, accounting for variation across hospital trusts. RESULTS 7437 patients undergoing metal-on-metal hip resurfacing were matched to 22,311 undergoing cemented total hip replacement; 8101 patients undergoing metal-on-metal hip resurfacing were matched to 24,303 undergoing uncemented total hip replacement. 10 year rates of cumulative mortality were 271 (3.6%) for metal-on-metal hip resurfacing versus 1363 (6.1%) for cemented total hip replacement, and 239 (3.0%) for metal-on-metal hip resurfacing versus 999 (4.1%) for uncemented total hip replacement. Patients undergoing metal-on-metal hip resurfacing had an increased survival probability (hazard ratio 0.51 (95% confidence interval 0.45 to 0.59) for cemented hip replacement; 0.55 (0.47 to 0.65) for uncemented hip replacement). There was no evidence for an interaction with age or sex. CONCLUSIONS Patients with hip osteoarthritis undergoing metal-on-metal hip resurfacing have reduced mortality in the long term compared with those undergoing cemented or uncemented total hip replacement. This difference persisted after extensive adjustment for confounding factors available in our data. The study results can be applied to matched populations, which exclude patients who are very old and have had complex total hip replacements. Although residual confounding is possible, the observed effect size is large. These findings require validation in external cohorts and randomised clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk of cancer in first seven years after metal-on-metal hip replacement compared with other bearings and general population: linkage study between the National Joint Registry of England and Wales and hospital episode statistics OPEN ACCESS

Objective To determine whether use of metal-on-metal bearing surfaces is associated with an increased risk of a diagnosis of cancer in the early years after total hip replacement and specifically with an increase in malignant melanoma and haematological, prostate, and renal tract cancers. Design Linkage study with multivariable competing risks flexible parametric survival model to examine the i...

متن کامل

Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

BACKGROUND Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according ...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing.

This study compared component wear rates and pre-revision blood metal ions levels in two groups of failed metal-on-metal hip arthroplasties: hip resurfacing and modular total hip replacement (THR). There was no significant difference in the median rate of linear wear between the groups for both acetabular (p = 0.4633) and femoral (p = 0.0872) components. There was also no significant difference...

متن کامل

Ongoing problems with metal-on-metal hip implants.

Major advances in total hip replacement have occurred since the prosthesis was first developed by Charnley in the 1960s. Yet substantial concerns currently exist over newer hip implants as a result of rising revision rates and increased risk of cancer. By the 1980s revision rates of total hip replacements were as low as 20% after 15 years of follow-up. Throughout this era, the main focus was re...