Analysis of polyethylene wear in plain radiographs

نویسندگان

  • Maiken Stilling
  • Kjeld Søballe
  • Niels Trolle Andersen
  • Kristian Larsen
  • Ole Rahbek
چکیده

BACKGROUND AND PURPOSE Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs. METHODS We used either 1, 2, or 6 anteroposterior (AP) hip radiographs of 11 patients from a clinical THA series with 12 years of follow-up, and measured the PE wear with the software PolyWare 3D Pro. Repeatability within and concurrent validity between the different numbers of radiograph strategies were assessed using limits of agreement (LOAs) and bias. RESULTS Observed median wear (range) in mm was 3.4 (1.6-4.6), 2.3 (0.7-4.9), and 4.0 (2.6-6.2) for the 1-, 2-, and 6-radiograph strategies. For repeatability, no bias (p > 0.41) was observed. LOAs around the bias were + or - 0.6, + or - 0.4, and + or - 1.2 mm for the 1-, 2-, and 6-radiograph strategies. For concurrent validity, a bias (+ or - LOA) between all pairwise comparisons was observed (p < 0.02) with 0.8 mm (+ or - 2.5) between the 1- and 2-radiograph strategies, 1.0 mm (+ or - 2.2) between the 1- and 6-radiograph strategies, and 1.8 mm (+ or - 1.2) between the 2- and 6-radiograph strategies. INTERPRETATION The number of radiographs used for wear measurement with a shadow-casting analysis method on plain AP radiographs influences the amount of linear wear measured. Results of PE wear obtained with PolyWare in studies using a different number of radiographs are not comparable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis

Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...

متن کامل

The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty

BACKGROUND AND PURPOSE Radiostereometric analysis (RSA) is a highly accurate tool for assessment of polyethylene (PE) wear in total hip arthroplasty (THA); however, PE wear measurements in clinical studies are often limited to plain radiographs. We evaluated the agreement between PE wear measured with PolyWare software, which uses plain radiographs, and by model-based RSA, which uses stereo rad...

متن کامل

Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups

A new 2-D radiographic wear measurement system has been developed which enables the low wear of highly cross-linked polyethylene acetabular cups to be accurately and precisely measured from standard, pelvis radiographs. The software was validated using radiographic images of a measurement jig which could vary the cup orientation and simulate the effect of pelvic tilt/rotation. Wear was simulate...

متن کامل

Automated assessment of polyethylene wear in cemented acetabular components using anteroposterior radiographs of total hip replacements

Polyethylene wear in the acetabular components of hip prostheses is implicated in loosening and failure. Radiographic measurement of wear is used to identify patients at risk and to assess prosthesis designs. This paper focuses on analysis of prostheses with cemented acetabular cups from anteroposterior (AP) radiographs. The articular surface of the femoral head and the acetabular rim marker ar...

متن کامل

Accuracy of measurement of polyethylene wear with use of radiographs of total hip replacements.

BACKGROUND Although a number of methods are used to estimate polyethylene liner wear from radiographs of total hip replacements, there is no consensus with regard to the accuracy of these methods. The purpose of this study was to compare the accuracy of several such measurement methods with use of both laboratory radiographs and routine clinical radiographs. METHODS A phantom apparatus was de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2009