A flattening filter free photon treatment concept evaluation with Monte Carlo.

نویسندگان

  • U Titt
  • O N Vassiliev
  • F Pönisch
  • L Dong
  • H Liu
  • R Mohan
چکیده

In principle, the concept of flat initial radiation-dose distribution across the beam is unnecessary for intensity modulated radiation therapy. Dynamic leaf positioning during irradiation could appropriately adjust the fluence distribution of an unflattened beam that is peaked in the center and deliver the desired uniform or nonuniform dose distribution. Removing the flattening filter could lead to reduced treatment time through higher dose rates and reduced scatter, because there would be substantially less material in the beam; and possibly other dosimetric and clinical advantages. This work aims to evaluate the properties of a flattening filter free clinical accelerator and to investigate its possible advantages in clinical intensity modulated radiation therapy applications by simulating a Varian 2100-based treatment delivery system with Monte Carlo techniques. Several depth-dose curves and lateral dose distribution profiles have been created for various field sizes, with and without the flattening filter. Data computed with this model were used to evaluate the overall quality of such a system in terms of changes in dose rate, photon and electron fluence, and reduction in out-of-field stray dose from the scattered components and were compared to the corresponding data for a standard treatment head with a flattening filter. The results of the simulations of the flattening filter free system show that a substantial increase in dose rate can be achieved, which would reduce the beam on time and decrease the out-of-field dose for patients due to reduced head-leakage dose. Also close to the treatment field edge, a significant improvement in out-of-field dose could be observed for small fields, which can be attributed to the change in the photon spectra, when the flattening filter is removed from the beamline.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...

متن کامل

Investigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator

Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...

متن کامل

Advantages and disadvantages of removed flattening filter Linac: A Monte Carlo study on full quantitative dosimetric data of 18 MV-Varian Linac

Introduction: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical propert...

متن کامل

Measurements of Photon Beam Flattening Filter Using an Anisotropic Analytical Algorithm and Electron Beam Employing Electron Monte Carlo

  Introduction: This study aimed to report the measurement of photon and electron beams to configure the Analytical Anisotropic Algorithm and Electron Monte Carlo used in clinical treatment. Material and Methods: All measurements were performed in a large water phantom using a 3-dimensional scanning system (PTW, Germany). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2006