Anticoagulants and the Björk-Shiley prosthesis. Experience of 390 patients.
نویسندگان
چکیده
From September 1972 to January 1975, 390 patients underwent valve replacement using the Björk-Shiley tilting disc prosthesis. For the group as a whole hospital mortality was 13.3 per cent and was lowest in those undergoing isolated mitral or aortic valve replacement (5.3 and 9.4%, respectively). Available for follow-up were 209 patients of whom 123 were maintained on dipyridamole and 96 on warfarin. Thromboembolic complications were significantly (P less than 0.01) commoner in the dipyridamole (28 of 123, 22%) than warfarin (6 of 86, 7%) treated group. In the dipyridamole treated group the incidence of thromboembolic complications was similar whichever valve was replaced and thromboembolic complications were responsible for 14 of the 28 late deaths. In the warfarin treated group thromboembolic complications only occurred in patients with a mitral prosthesis. Anticoagulation is indicated for all patients with this prosthesis wherever inserted.
منابع مشابه
Thrombotic obstruction of the Björk-Shiley valve: the Glasgow experience.
Thrombotic obstruction is the most feared complication of the Björk-Shiley tilting disc prosthesis. From 1971 to 1982 1186 Björk-Shiley valves were implanted in 900 patients. There were 93 deaths in hospital. Eight hundred and seven patients have been followed for a total of 4146 patient years; 14 patients were lost to follow up. Nineteen cases of thrombotic obstruction were identified at necro...
متن کاملAortic valve replacement in patients over 70 years.
Twenty-seven patients 70 years of age or more were operated upon with aortic valvular replacement with an early mortality rate of 7%. No more patients died during a mean follow-up period of 28 months. The Björk-Shiley standard tilting disc valve was implanted in 15 cases and the new convexo-concave model in 12 cases. Sixty-seven per cent of the patients had narrow aortic roots (21 and 23 mm pro...
متن کاملIntravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...
متن کاملHaemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis.
The present study reports on the incidence and degree of intravascular haemolysis in 33 patients with Björk-Shiley tilting disc prosthesis and in 34 patients with Lillehei-Kaster pivoting disc valve prosthesis in the mitral position examined 12 to 24 months after the operation. Serum haptoglobin, serum lactate dehydrogenase, serum bilirubin, and haemoglobin estimations were performed. Significa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 40 5 شماره
صفحات -
تاریخ انتشار 1978