Assessment of consistency in contouring of normal‐tissue anatomic structures

نویسندگان

  • Dawn C. Collier
  • Stuart S. C. Burnett
  • Mayankkumar Amin
  • Stephen Bilton
  • Christopher Brooks
  • Amanda Ryan
  • Dominique Roniger
  • Danny Tran
  • George Starkschall
چکیده

The purpose of this work is to estimate the uncertainty in the manual contouring of normal anatomical structures. The heart, esophagus, and spinal cord were contoured manually on six sets of computed tomography images by six dosimetrists whose experience ranged from 1 year to over 15 years. To determine the differences between inter- and intraobserver variations, each data set was contoured by one of the dosimetrists five times and once each by the five other dosimetrists. The magnitude of the discrepancies in delineating the contours was assessed. Intradosimetrist contouring discrepancies were as follows: esophagus, average 0.3 cm and maximum 2.9 cm; heart, average 0.5 cm and maximum 7.6 cm; and spinal cord, average 0.1 cm and maximum 0.7 cm. Interdosimetrist contouring discrepancies were as follows: esophagus, average 0.4 cm and maximum 3.1 cm; heart, average 0.7 cm and maximum 8.1 cm; and spinal cord, average 0.2 cm and maximum 0.9 cm. Significant discrepancies can occur when normal anatomic structures are contoured manually. Interdosimetrist discrepancies are typically slightly greater than intradosimetrist discrepancies. The magnitude of the discrepancies does not appear to be correlated to the experience of the dosimetrist.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computed Tomographic Anatomy and Topography of the Lower Respiratory System of the Southern White-Breasted Hedgehog (Erinaceus concolor)

Objective- The aim of this study was preparing detailed anatomic images of the thoracic cavity of the southern white-breasted hedgehog using the non-invasive computed tomography (CT) technique.Design- Descriptive study.Animals- Five southern white-breasted hedgehog (Erinaceus concolor) which is a species native to the Middle East, Anatolia, Transcaucasia, and Iran. Since some people...

متن کامل

Dosimetric uncertainties of three‐dimensional dose reconstruction from two‐dimensional data in a multi‐institutional study

Inconsistencies in the treatment planning process leading to dosimetric uncertainties may affect conclusions drawn from interinstitutional radiation oncology clinical trials. The purpose of this study was to assess the dosimetric uncertainties resulting from the process of reconstructing three-dimensional dose distributions from two-dimensional treatment plan information provided by participati...

متن کامل

I-42: Advanced Ultrasonic Techniques in The Assessment of Early Human Development

Background: To evaluate the role of 3D, 4D and color Doppler ultrasound (US) in the assessment of early human development. Materials and Methods: 380 women with uncomplicated early pregnancy between 5 and 14 weeks were evaluated by 3D, 4D and color Doppler US. Results: Regression analysis revealed exponential rise of the gestational sac volume with gestational age throughout the first trimester...

متن کامل

Anatomic Variations of Brachial Plexus: A Cadaveric Study

Introduction: The brachial plexus is responsible for the innervation to the upper limb and some parts of the thorax. Variations in the branching of the brachial plexus are common and have been reported in 65.3% of the population. The variations (Atypical communication) of brachial plexus have significant clinical and surgical importance. Methods: In this study 10 upper limbs which belonged...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2003