Predictive, error-compensating kinetic method for enzymatic quantification of creatinine in serum.
نویسندگان
چکیده
Here we describe an error-compensating kinetic-based method for the enzymatic quantification of creatinine in serum. The method, which has a large linear range and very low dependency on experimental variables that influence enzyme activity, is based on the use of creatinine amidohydrolase in a four-step coupled reaction sequence to generate a product that is monitored photometrically. We collected data for absorbance vs time during two to four half-lives of each reaction and fit a first-order model to the data to compute the total absorbance change that would be measured if the reaction were monitored to completion. Computed values of absorbance change agreed well with measured values and varied linearly with creatinine concentration in the sample throughout the range examined: 44 to 1326 mumol/L. A twofold change in enzyme activity in the final reaction mixture (3.3 to 6.6 kU/L) produced changes of only 12% and 4% for creatinine concentrations of 44 and 353 mumol/L, respectively. Results (y) for 39 serum samples that contained creatinine concentrations between 20 and 1800 mumol/L agreed well with liquid-chromatographic results (x), yielding linear least-squares statistics of y = (1.03 +/- 0.01) x + (5 +/- 5) mumol/L (r = 0.995, Sy.x = 37 mumol/L). We conclude that the predictive kinetic approach is a robust method for the quantification of creatinine in serum.
منابع مشابه
A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.
We evaluated a new, simple, enzymatic kinetic method from Wako Chemicals GmbH in comparison with a kinetic Jaffé method by using isotope dilution-mass spectrometry (ID-MS) as a reference method. An ID-MS-calibrated serum standard was used. Both the enzymatic and the Jaffé method correlated well with ID-MS, except for sera with high concentrations of bilirubin. Ethyl acetoacetate, acetone, and g...
متن کاملEvaluation of an Enzymatic Method for Determining Serum Creatinine Assay
The enzymatic method for the determination of serum creatinine is accepted as one of the standard method in a clinical laboratory. The enzymatic method for the determination of serum creatinine was optimized for use with Merilyzer AutoQuant-400 auto analyzer and its performance characteristics were practically compared with Jaffe’s Kinetic. Effects of some interfering substances like Serum bili...
متن کاملApplicability of common reference intervals for serum creatinine concentrations to the Croatian population.
BACKGROUND In accordance with an ongoing activity for worldwide harmonization based on traceability in laboratory methods, the goal of this study was to validate the applicability of recommended "common" reference intervals for serum creatinine concentrations using a specific enzymatic method to the Croatian population. METHODS The reference group consisted of 240 healthy subjects (120 males ...
متن کاملمطالعه سیستاتین C سرم و کراتینین سرم به عنوان شاخص مطمئن در تشخیص نارسایی کلیوی بیماران فشار خونی
Background & Aims : In the past serum creatinine concentration was used as one of the important markers for early detection of kidney disorders, however recent studies suggest serum cystatin C to be a better marker. Therefore in this study we compared the diagnostic value of cystatin C with serum creatinine to evaluate kidney function in patients with high blood pressure. Materials & Meth...
متن کاملIncremental Predictive Command of Velocity to Be Gained Guidance Method
In this paper, a new incremental predictive guidance method based on implicit form of velocity to be gained algorithm is proposed. In this approach, the generalized incremental predictive control (GIPC) approach is applied to the linearized model for compensating the guidance error. Instead of using the present state in popular model based predictive controller (MPC), in the new method both pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 37 8 شماره
صفحات -
تاریخ انتشار 1991