The physiologic state of Escherichia coli O157:H7 does not affect its detection in two commercial real-time PCR-based tests.

نویسندگان

  • Rong Wang
  • John W Schmidt
  • Terrance M Arthur
  • Joseph M Bosilevac
چکیده

Multiplex real-time PCR detection of Escherichia coli O157:H7 is an efficient molecular tool with high sensitivity and specificity for meat safety assurance. The Biocontrol GDS(®) and DuPont Qualicon BAX(®)-RT rapid detection systems are two commercial tests based on real-time PCR amplification with potential applications for quantification of specific E. coli O157:H7 gene targets in enriched meat samples. However, there are arguments surrounding the use of these tests to predict pre-enrichment concentrations of E. coli O157:H7, as well as arguments pertaining to the influence of non-viable cells causing false positive results. The present study attempts to illustrate the effects of different bacterial physiologic states and the presence of non-viable cells on the ability of these systems to accurately measure contamination levels of E. coli O157:H7 in ground beef. While the PCR threshold cycle (C(T)) values of these assays showed a direct correlation with the number of bacteria present in pure cultures, this was not the case for ground beef samples spiked with various levels of injured or healthy cells. Furthermore, comparison of post-enrichment cell densities of bacteria did not correlate with injured or healthy cell numbers inoculated before enrichment process. Ground beef samples spiked with injured or healthy cells at different doses could not be distinguished by C(T) values from either assay. In addition, the contribution of nonviable cells in generating positive real-time PCR signals was investigated using both assays on pre-enriched and post-enriched beef samples, but only if inoculated at levels of 10(6) cells/sample or higher, which are levels not typically seen in ground beef.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Viable But Non-Culturable State of Escherichia coli O157:H7 Using Reverse Transcription PCR

Background and Aims: Many bacteria including Escherichia coli may enter into a viable but non-culturable (VBNC) state under unfavorable stresses, which are unable to be detected by culture-based methods. In this study, the use of Reverse Transcription PCR (RT-PCR) for detection of VBNC state of E. coli O157:H7 was investigated. Materials and Methods:  Escherichia. coli O157:H7 was inoculated i...

متن کامل

Identification of Escherichia coli O157: H7 from Slaughtered Beef in Mashhad Using Biochemical and Molecular Methods

Background and Aims: Escherichia coli O157:H7 is one of the main causes of transmitted diseases by food, including meat and meat products. The purpose of this study was to investigate the prevalence of E. coli O157:H7 contamination in Mashhad with the detection of rfbE gene. Materials and Methods: For this study, 148 slaughtered beef samples from Mashhad (spring to winter, 2018) were randomly ...

متن کامل

PCR detection of Escherichia coli O157:H7 directed from slaughtered cattle in Shiraz, Iran

  Escheric hia coli O157:H7 lives in the intestines of healthy cattle, and can contaminate meat during slaughtering pr actices . Detection of the low infectious dosage of bacterium requires a sensitive method. We developed polymerase chain reaction (PCR) assays to detect the gene Stx2 irrespective of the bacterial serotype. In this study, the detection limit of the PCR protocol in detecting Stx...

متن کامل

Use of the duplex TaqMan PCR system for detection of Shiga-like toxin-producing Escherichia coli O157.

Real-time PCR assays have been applied for the detection and quantification of pathogens in recent years. In this study two combinations of primers and fluorescent probes were designed according to the sequences of the rfb(Escherichia coli O157) and stx2 genes. Analysis of 217 bacterial strains demonstrated that the duplex real-time PCR assay successfully distinguished the Escherichia coli O157...

متن کامل

Performance comparison of a fliC(h7) real-time PCR assay with an H7 latex agglutination test for confirmation of the H type of Escherichia coli O157:H7.

Escherichia coli O157:H7 is a foodborne pathogen that causes hemorrhagic colitis and hemolytic uremic syndrome. Positive identification of E. coli O157:H7 is made using biochemical tests and specific antisera or latex agglutination reagents for the O157 and H7 antigens. However, under certain conditions, some E. coli O157:H7 isolates can appear to be nonreactive with H7 antisera and may require...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Food microbiology

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 2013