Removal of dissolved oxygen from water: A comparison of four common techniques.

نویسندگان

  • I B Butler
  • M A Schoonen
  • D T Rickard
چکیده

Four common techniques for the removal of dissolved oxygen from water have been examined: boiling at 1 atm, boiling under reduced pressure, purging with N(2) and sonication under reduced pressure. After treatment, the residual oxygen in solution was analysed by the Winkler method. Nitrogen purging for 20-40 min at flow rate of 25 mL/s was found to be the most effective oxygen removal method. Boiling at 1 atm was found to be the least effective. None of the techniques evaluated here lead to complete removal of oxygen. The concentration of residual dissolved oxygen after purging for 20-40 minutes with nitrogen is 0.2-0.4 ppm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Gene Expression Programming to water dissolved oxygen concentration prediction

This research based on record and collected data from four stations at Eymir Lake, Turkey, which are monitored daily in seven months. Water quality monitoring using former methods are time-needed and expensive, while the application of gene expression programming is more understandable, rapid, and reliable which is used in this article to provide a prediction for dissolved oxygen. The concentra...

متن کامل

Development of Advection-Dispersion Model of Dissolved Oxygen Using Numerical Solutions

Urban and industrial wastewaters are considered as the most contaminant of surface water. Entrance   of these pollutants to the river reduces the concentration of dissolved oxygen and aquatic life will be threatened. So, one of the main qualitative characteristics of water resources management is the concentration of dissolved oxygen. The base of the   developed model in this investigation is t...

متن کامل

The effects of physicochemical parameters on fish distribution in Eğirdir Lake, Turkey

The present study was conducted based on the fish species and physicochemical parameters of Eğirdir Lake. Sampling was carried out monthly from January through December 2010 between 9 am and 11 am. The parameters measured were water temperature, depth, secchi disk depth, turbidity, dissolved oxygen, saturation of dissolved oxygen, pH, conductivity, chloride, hardness, calcium, magnesium, bicarb...

متن کامل

The effects of physicochemical parameters on fish distribution in Eğirdir Lake, Turkey

The present study was conducted based on the fish species and physicochemical parameters of Eğirdir Lake. Sampling was carried out monthly from January through December 2010 between 9 am and 11 am. The parameters measured were water temperature, depth, secchi disk depth, turbidity, dissolved oxygen, saturation of dissolved oxygen, pH, conductivity, chloride, hardness, calcium, magnesium, bicarb...

متن کامل

Modeling and optimization of oil refinery wastewater chemical oxygen demand removal in dissolved air flotation system by response surface methodology

In this present study the dissolved air flotation (DAF) system was investigated for the treatment of Kermanshah Oil Refinery wastewater. The effect of three parameters on flotation efficiency including of flow rate (outflow from the flotation tank), saturation pressure and coagulant dosage on chemical oxygen demand (COD) removal was examined experimentally. All the experiments were done under a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 1994