Gas-Cooling of Multiple Short Inline Disks in Flow Along Their Axis

نویسنده

  • Dimitrios Papadopoulos
چکیده

To learn about cooling of gas quenched batches, this paper reports on numerical predictions of local and average convective heat transfer coefficients, and overall pressure drops, on batches of five axially aligned, constant temperature, short cylindrical disks 25 cm diameter, 5 cm thickness with and without a concentric hole, with interdisk spacings of 5–20 cm, in axial turbulent flows of 20 bar nitrogen gas at inlet speeds from 10 m/s to 100 m/s, corresponding to Reynolds numbers Re between 3.27 10 and 32.7 10. The heat transfer coefficients along the disk surfaces vary strongly up to a worse case of two orders of magnitude for the upstream disk. This nonuniformity is much lower for the disks downstream, especially after spacing is increased beyond 0.1 m. As expected, the upstream disk exhibited rather different heat transfer coefficients than the ones downstream, the magnitude of the heat transfer coefficient and its uniformity increased with the interdisk spacing, and varied by a factor of about 4–5 along the surfaces. The average heat transfer coefficient Nusselt number, Nu on the disks increased approximately with Reynolds number as Re. Re did not have much influence on the nonuniformity of Nu on the disk surfaces. The overall pressure drop along the flow increases with the interdisk spacing, rising by about 60 % as the spacing is increased from 0.05 m to 0.20 m. The presence of a hole increases the heat transfer coefficient in all cases. Some suggestions for reducing the heat transfer coefficient nonuniformity are made.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Cold Flows in the Assembly of Galaxy Disks

We use high resolution cosmological hydrodynamical simulations to demonstrate that cold flow gas accretion, particularly along filaments, modifies the standard picture of gas accretion and cooling onto galaxy disks. In the standard picture, all gas is initially heated to the virial temperature of the galaxy as it enters the virial radius. Low mass galaxies are instead dominated by accretion of ...

متن کامل

Cooling flows within galactic haloes: the kinematics and properties of infalling multi-phase gas

We study the formation of disks via the cooling flow of gas within galactic haloes using smoothed particle hydrodynamics simulations. These simulations resolve mass scales of a few thousand solar masses in the gas component for the first time. Thermal instabilities result in the formation of numerous warm clouds that are pressure confined by the hot ambient halo gas. The clouds fall slowly onto...

متن کامل

Numerical Simulation Of the Componend Angles Effects On Adiabatic Film Cooling Effectiveness

Abstract Film Cooling Adiabatic Effectiveness on a Profile of a Gas Turbine blade that Using Holes with 45 Degree Combined Angles to the Flow Direction and Radial Along the Attack Edge as well as 25 Degree Angles to the Flow Direction and Surface Area of the Attack Edge Area and 35 degrees relative to the outlet hole suefaces along stagnation line, Under a specified blowing ratios, using the Re...

متن کامل

آنالیز انرژی و اکسرژی یک برج سرمایش-رطوبت‌زنی گاز همسو بر مبنای نتایج مدلسازی ریاضی و شبیه‌سازی

Beginning with a discussion of energy and exergy analysis definitions, the presented study provides a descriptive mathematical model for energy and exergy analysis for a co-current gas cooling tower. For this purpose using conservation laws of mass, energy and momentum, the variation of temperature and enthalpy of gas and liquid streams are predicted along the tower length and are used in order...

متن کامل

Optimal Short-Term Scheduling of Multi-Chiller Plants Considering Energy Requirement of Cooling Towers, Pumps and Chillers

During extremely hot summer days, air conditioning systems are known as major electricity consumers in residential, commercial and industrial sectors. Moreover, high energy requirement of multiple-chiller plants may cause an interconnected power grid be faced with annual on-peak electrical demand, load-generation mismatch, voltage collapse and catastrophic wide area blackout. Therefore, this pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008