Fluorescence dilution technique for measurement of cardiac output and circulating blood volume in healthy human subjects.

نویسندگان

  • Jean-Michel I Maarek
  • Daniel P Holschneider
  • Eduardo H Rubinstein
چکیده

BACKGROUND The authors previously validated in an animal model a new indicator dilution technique for measuring cardiac output and circulating blood volume by recording transcutaneously the fluorescence of circulating indocyanine green with an optical probe placed on the skin surface. The current study compared fluorescence dilution recordings recorded from several locations on the human face in terms of signal intensity and stability and estimated the subjects' cardiac output and circulating blood volume from the recordings. METHODS Fluorescence dilution traces were recorded transcutaneously in six healthy human volunteers after rapid intravenous injection of 1 mg indocyanine green. Three placements of the optical probe were tested: the nose ala, the ear lobe, and the temple area. In three subjects, the recordings were calibrated in terms of circulating indocyanine green concentration to estimate cardiac output and circulating blood volume. RESULTS Fluorescence dilution traces had the same duration for the three locations, but the recordings obtained from the nose ala and the ear lobe were twice as intense as those from the temple. The fluorescence intensity at each site was linearly related to the local laser Doppler perfusion index. The coefficient of variation for the area under the first pass curve (inversely proportional to cardiac output) was approximately 6% for triplicate measurements at the same location. Cardiac output and circulating blood volume derived from the fluorescence recordings were in the normal range. CONCLUSIONS The study demonstrates that intense and reproducible fluorescence dilution signals can be measured transcutaneously in healthy humans and could potentially be used to measure cardiac output and circulating blood volume minimally invasively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اثر درشت مغذی‌ها بر پاسخ‌های قلبی - عروقی در افراد سالم و دیابتی نوع II

Introduction: It is felt that there is an information void regarding the effect of macronutrients on cardiovascular responses such as cardiac output,heart rate,stroke volume,systolic blood pressure,diastolic blood pressure and mean arterial pressure, therefore, this study was designed to explore these effects at Shaheed Beheshti University in 2001. Materials & Methods: This clinical trial was ...

متن کامل

Measurement of stroke volume by the vibrocardiogram.

An examination has been made of the relationship between stroke volume measured by dye dilution and left ventricular isovolumetric contraction and ejection times as measured by the vibrocardiogram. These studies were performed in 10 normal subjects under postural alterations, and in 11 patients recovering from acute myocardial infarction. gression analyses of the data showed that ejection t h e...

متن کامل

Mechanisms for the elevation of blood pressure in human renal disease. Preliminary report.

Detailed hemodynamic studies were carried out in 99 subjects with chronic nonuremic renal disease and 17 healthy subjects. The earliest hemodynamic abnormality found in normotensive renal patients was a raised circulating blood volume and an increased cardiac output. The blood pressure remained normal as long as the peripheral vascular bed (arteriolar and venous) adjusted to these conditions. W...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

A mathematical model of dilution curves for flow study.

THE PURPOSE of this paper is to present a mathematical model of dilution curves obtained by precordial detection of concentration of an intravenously injected radioactive tracer. The analysis makes possible formulation of equations relating parameters of the curve to cofunctions of the curve, such as cardiac output, central circulating blood volume, and volume of heart chambers. The presentatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 106 3  شماره 

صفحات  -

تاریخ انتشار 2007