QUESTION Is ventilator-induced hyperinflation in sidelying more effective than sidelying alone in removing secretions and improving respiratory mechanics in ventilated patients with pulmonary infection? DESIGN Randomised crossover trial with concealed allocation and intention-to-treat analysis. PARTICIPANTS 30 mechanically ventilated patients with pulmonary infection in an adult intensive care unit. INTERVENTION The experimental intervention was 30 minutes of ventilator-induced hyperinflation using pressure support ventilation in sidelying; the control intervention was 30 minutes of sidelying. Participants received both interventions on the same day, with a five-hour washout period between them. OUTCOME MEASURES Secretion clearance was measured as sputum volume retrieved during the intervention. Respiratory mechanics were measured as static compliance and total resistance of the respiratory system before and after the intervention. RESULTS The experimental intervention cleared 1.3 ml (95% CI 0.5 to 2.2) more secretions than the control. After ventilator-induced hyperinflation in sidelying, respiratory compliance had increased 4.7 ml/cmH(2)O (95% CI 2.6 to 6.8) more than in sidelying alone. There was no difference in total resistance of the respiratory system between the interventions (mean difference 0.3 cmH(2)O/l/s, 95% CI -0.8 to 1.3). CONCLUSION The application of hyperinflation using pressure support ventilation in mechanically ventilated patients with pulmonary infection improves secretion clearance and increases static compliance of the respiratory system.
منابع مشابه
Can the Flutter Valve improve respiratory mechanics and sputum production in mechanically ventilated patients? A randomized crossover trial.
OBJECTIVE The Flutter Valve (Varioraw SARL, Scandipharm Inc, Birmingham, AL) has proven efficacy in hypersecretive spontaneously ventilated patients. This study was designed to evaluate whether an airway clearance protocol using the Flutter Valve can affect the therapeutic and physiologic outcomes in mechanically ventilated patients with pulmonary infection. METHODS In a randomized crossover ...
متن کاملExpiratory rib cage Compression in mechanically ventilated subjects: a randomized crossover trial [corrected].
BACKGROUND Expiratory rib cage compression (ERCC) has been empirically used by physiotherapists with the rationale of improving expiratory flows and therefore the airway clearance in mechanically ventilated patients. This study evaluates the acute mechanical effects and sputum clearance of an ERCC protocol in ventilated patients with pulmonary infection. METHODS In a randomized crossover stud...
متن کاملتأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی
Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...
متن کاملThe Mapleson C circuit clears more secretions than the Laerdal circuit during manual hyperinflation in mechanically-ventilated patients: a randomised cross-over trial.
QUESTION What is the effect of the Mapleson C circuit compared with the Laerdal circuit in removing secretions and improving ventilation and gas exchange during manual hyperinflation? DESIGN Prospective, randomised, cross-over trial. PARTICIPANTS Twenty patients from a tertiary-level intensive care unit who were being mechanically ventilated. INTERVENTION Manual hyperinflation in side-lyi...
متن کاملComparison of the effectiveness of manual and ventilator hyperinflation at different levels of positive end-expiratory pressure in artificially ventilated and intubated intensive care patients.
BACKGROUND Manual hyperinflation (MHI) and ventilator hyperinflation (VHI) are two methods of recruitment maneuvers used in ventilated patients to improve lung compliance and secretion mobilization. The use of VHI may minimize the adverse effects of disconnection from the ventilator, but it is uncertain whether high levels of positive end-expiratory pressure (PEEP) would decrease the peak expir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Australian journal of physiotherapy
دوره 55 4 شماره
صفحات -
تاریخ انتشار 2009