Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer.
نویسندگان
چکیده
PURPOSE To study the interfraction reproducibility of breath-holding using active breath control (ABC), and to develop computerized tools to evaluate three-dimensional (3D) intrathoracic motion in each patient. METHODS AND MATERIALS Since June 2002, 11 patients with non-small-cell lung cancer enrolled in a Phase II trial have undergone four CT scans: one during free-breathing (reference) and three using ABC. Patients left the room between breath-hold scans. The patient's breath was held at the same predefined phase of the breathing cycle (about 70% of the vital capacity) using the ABC device, then patients received 3D-conformal radiotherapy. Automated computerized tools for breath-hold CT scans were developed to analyze lung and tumor interfraction residual motions with 3D nonrigid registration. RESULTS All patients but one were safely treated with ABC for 7 weeks. For 6 patients, the lung volume differences were <5%. The mean 3D displacement inside the lungs was between 2.3 mm (SD 1.4) and 4 mm (SD 3.3), and the gross tumor volume residual motion was 0.9 mm (SD 0.4) to 5.9 mm (SD 0.7). The residual motion was slightly greater in the inferior part of the lung than the superior. For 2 patients, we detected volume changes >300 cm(3) and displacements >10 mm, probably owing to atelectasia and emphysema. One patient was excluded, and two others had incomplete data sets. CONCLUSION Breath-holding with ABC was effective in 6 patients, and discrepancies were clinically accountable in 2. The proposed 3D nonrigid registration method allows for personalized evaluation of breath-holding reproducibility with ABC. It will be used to adapt the patient-specific internal margins.
منابع مشابه
Lung volume reproducibility under ABC control and self‐sustained breath‐holding
An Active Breathing Coordinator (ABC) can be employed to induce breath-holds during CT imaging and radiotherapy of lung, breast and liver cancer, and recently during lung cancer MRI. The apparatus measures and controls respiratory volume, hence subject lung volume reproducibility is its principal measure of effectiveness. To assess ABC control quality, the intra-session reproducibility of ABC-i...
متن کاملLung Deformation Estimation with Non-rigid Registration for Radiotherapy Treatment
A main challenge in radiotherapy is to precisely take into account organs deformation and motion in order to adapt the treatment to each patient. This is particularly important in lung cancer where breathing leads to large displacements. In this work, breath holding techniques (with Active Breath Control device) were used to reduce movements during treatment. We study thorax and lung deformatio...
متن کاملFirst MRI application of an active breathing coordinator
A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC t...
متن کاملNonrigid versus rigid registration of thoracic 18F-FDG PET and CT in patients with lung cancer: an intraindividual comparison of different breathing maneuvers.
UNLABELLED In lung cancer, (18)F-FDG PET, CT, and (18)F-FDG PET/CT are used for noninvasive staging and therapy planning. Even with improved image registration techniques-especially in the modern hybrid PET/CT scanners-inaccuracies in the fusion process may occur, leading to errors in image interpretation. The aim of this study was to investigate by an intraindividual analysis whether, in compa...
متن کاملThe application of active respiratory gating technology in lung cancer radiotherapy
Objective: The technology of ABC ( Active Breathing Control) was used in breath-holding time in order to improve the accuracy of radiotherapy for lung cancer patients, and the influence of respiratory movement on diaphragm motion was analyzed and evaluated, in addition the feasibility and limitation of ABC was also assessed. Methods: 15 lung cancer patients were selected for the training of ABC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 61 2 شماره
صفحات -
تاریخ انتشار 2005