Advanced bionics thin lateral and Helix II electrodes: a temporal bone study.

نویسندگان

  • Charles G Wright
  • Peter S Roland
  • Janusz Kuzma
چکیده

OBJECTIVE This study was performed to evaluate the insertional properties of two cochlear implant electrodes recently developed by Advanced Bionics Corporation. STUDY DESIGN Anatomic study using human cadaveric temporal bones. METHODS The electrode prototypes we tested are the Thin Lateral and Helix II arrays, which incorporate features designed to minimize insertional trauma. A total of eight electrodes (4 of each prototype) were evaluated after insertion into freshly fixed temporal bones. The electrodes were inserted by way of standard cochleostomies, and the specimens were subsequently dissected to assess electrode position, insertion depth, and intracochlear trauma. RESULTS Quantitative data regarding insertion depths and contact distances from the modiolus are presented for all electrodes tested. The mean insertion depths were 368 degrees for the Thin Lateral electrodes, which are designed to approximate the lateral cochlear wall, and 436 degrees for the Helix II electrodes, which occupy a more medial position in the scala tympani. No evidence of insertional trauma was observed with either electrode. The ease of insertion and absence of trauma were confirmed during additional trials in which electrode behavior was directly observed during insertion into previously opened cochleas. CONCLUSION Both electrodes performed favorably in our human temporal bone trials, and both arrays appear promising for clinical use, especially in patients with residual hearing in whom atraumatic insertion is an important objective.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of micro-CT to evaluate cochlear implant electrode position and intracochlear damage.

1. Balkany TJ, Connell SS, Hodges AVet al. Conservation of residual acoustic hearing after cochlear implantation. Otol Neurotol 2006;27:1083-8. 2. von Ilberg C, Kiefer J, Tillein Jet al. Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL; journal for oto-rhino-laryngology and its related specialties 1999;61:334-40. 3. Gantz BJ, Turner CW. Combining...

متن کامل

Comparative study of cochlear damage with three perimodiolar electrode designs.

OBJECTIVE To describe intracochlear insertion trauma caused by three perimodiolar cochlear implant electrodes. STUDY DESIGN Descriptive histological study of 15 human cadaver temporal bones. METHODS Fifteen cadaver temporal bones underwent surface preparation and were implanted with one of the following perimodiolar electrode arrays: Combi 40+PM (MedEl Corporation), HiFocus II (Advanced Bio...

متن کامل

Radiological and Histological Evaluation of Perimodular Electrodes: Impact on Cochlear Implant Development

Introduction: Different Perimodiolar electrodes were developed by many cochlear implant (CI) manufacturers in the past few years. Possible advantages are lower stimulation thresholds and a better channel separation. A position close to the modiolus can be facilitated by different means: preformed electrode shape (Nucleus ContourTM electrode, Cochlear Corp., Australia), additional positioning el...

متن کامل

Temporal Bone Osteomyelitis in a Child Closely Resembles Lateral Sinus Thrombosis: A Case Report

Introduction: Temporal bone osteomyelitis is more commonly seen in immunocompromised patients and is very rare in non-immunocompromised individuals. Mucormycosis is a fulminating fungal infection caused by Mucor which is a saprophytic fungus commonly seen in diabetic patients. Here we report a case of temporal bone osteomyelitis in a child with a traumatic history which was causing clinical fe...

متن کامل

Virtual channel discrimination is improved by current focusing in cochlear implant recipients.

Cochlear implant users' spectral resolution is limited by both the number of implanted electrodes and channel interactions between electrodes. Current steering (virtual channels) between two adjacent monopolar electrodes has been used to increase the number of spectral channels across the electrode array. However, monopolar stimulation is associated with large current spread and increased chann...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Laryngoscope

دوره 115 11  شماره 

صفحات  -

تاریخ انتشار 2005